<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>CADD &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/brand/cadd/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Wed, 08 Jul 2026 19:06:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>CADD &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>CADD Legacy Plus Pump</title>
		<link>https://auxomedical.com/products/cadd-legacy-plus-pump/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Thu, 02 Mar 2017 13:25:55 +0000</pubDate>
				<guid isPermaLink="false">http://auxomedical.com/product/cadd-legacy-plus-pump/</guid>

					<description><![CDATA[<p>The <strong>Legacy Plus Model 6500</strong> is the latest addition to the esteemed CADD family, renowned for its therapy-specific delivery systems. This innovative pump sets a new benchmark for continuous and intermittent ambulatory infusion, particularly in research settings. CADD pumps have enjoyed a stellar reputation for accuracy and durability since their inception in the early 1980s, and the CADD-Legacy PLUS model continues this tradition. Designed for both continuous and intermittent therapies, the pump comes with a single-use 50-/100-ml pump pouch, 2 AA alkaline batteries, and an operator's manual. Among its impressive features are an easy-to-read display for straightforward programming and troubleshooting, a cassette detection sensor, and occlusion sensors to alert users of any interruptions in fluid delivery. Additionally, the air-in-line detector ensures patient safety by detecting air presence in the administration set tubing. The ON/OFF key conserves battery life, while an event memory that records up to 1,000 events can be accessed via the CADD-DIPLOMAT PC Communications System. The pump's reliability means fewer therapy interruptions, and its programming flexibility, with infusion rates up to 125 mL/hr and dose volumes up to 1,000 ml, accommodates high-rate, high-volume therapies. Enhanced delayed start times and dosing parameters provide the adaptability needed for complex therapy regimens, ensuring that the internal clock keeps dosing on schedule.</p>
<p>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2017/06/CADD-Legacy-Plus-Pump-Auxo-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p><strong>Warranty: 6 Months</strong></p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/cadd-legacy-plus-pump/">CADD Legacy Plus Pump</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>CADD Legacy Plus Pump</h2>
<p>The Legacy Plus Model 6500 is the new member of the CADD family for therapy-specific delivery systems. These pumps sets the standard for continuous and intermittent ambulatory infusion in research. CADD pumps have an unparalleled track record of accuracy and durability dating back to the early 1980s. The CADD-Legacy PLUS pump is for continuous and intermittent therapies because performance runs in the family. Includes pump, single-use 50-/ 100-ml pump pouch, 2 AA alkaline batteries, and operator’s manual</p>
<h3>Features:</h3>
<ul>
<li>Easy to Read Display</li>
<li>Cassette Detection</li>
<li>Occlusion Detection: Upstream and downstream occlusion sensors are designed to alert the patient and clinician if interruption of fluid delivery occurs</li>
<li>Air-in-Line Detection: Air-in-line detector with Off, High- and Lowsensitivity settings is designed to alert the patient and clinician if air is present in the administration set tubing</li>
<li>ON/OFF Key-allows pump to be placed in low-power state and save battery life</li>
<li>Event Memory</li>
<li>CADD-DIPLOMAT PC Communications System</li>
<li>CADD pump reliability and durability can mean less down time and fewer interruptions to therapy</li>
<li>Infusion rates up to 125 mL/hr</li>
<li>Dose volumes up to 1,000 ml</li>
<li>Longer delayed start time and expanded dosing parameters provide added flexibility in meeting complex therapy requirements</li>
<li>Internal clock designed to keep dosing on schedule</li>
</ul>
<h3>Specs:</h3>
<ul>
<li>Weight: 13.8</li>
<li>Flow Rate range: 0-125 ml/hr</li>
<li>Volume Range: 1 ml-9,999 ml</li>
</ul>
<p><strong>6 Month Warranty</strong></p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/cadd-legacy-plus-pump/">CADD Legacy Plus Pump</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3641</post-id>	</item>
	</channel>
</rss>
