<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Sterilizers &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/product-category/sterilizers/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Sun, 15 Feb 2026 20:02:50 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>Sterilizers &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>Steris AMSCO Century SG-160 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sg-160-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:52:22 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86352</guid>

					<description><![CDATA[<div class="Message_messageTextContainer__w64Sc">
<div class="Message_selectableText__SQ8WH">
<div class="Markdown_markdownContainer__Tz3HQ">
<div class="Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9">
<p>The <strong>Steris AMSCO Century SG-160 Scientific Steam Sterilizer</strong> is a large-capacity, gravity-based sterilizer designed for rapid, reliable sterilization of heat- and moisture-stable materials. Featuring a spacious <strong>26" x 37.5" x 60" (960 liters)</strong> chamber, it provides ample room to sterilize liquids, media, glassware, instruments, clothing, and laboratory waste efficiently. Equipped with versatile cycles—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SG-160 offers flexible, high-quality sterilization tailored to diverse laboratory needs. Its user-friendly interface includes a fluorescent display, impact printer for documentation, help screens for troubleshooting, and PC compatibility for easy data management. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it ensures safety and consistent performance. Optional stainless steel side panels are available for added durability, making the SG-160 an ideal solution for demanding scientific  sterilization applications.</p>
</div>
</div>
</div>
</div>
<div>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-160-scientific-steam-sterilizer/">Steris AMSCO Century SG-160 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SG-160 Scientific Steam Sterilizer</h2>
</div>
<p>Steris SG-160 Gravity Steam Sterilizers are designed for fast, efficient sterilization. The SG-160 gravity sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 60″ (960 L) chamber, the SG160 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 60″ chamber (960 Liters)</li>
<li>Gravity Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<p>Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options</p>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8.</div>
<div>
<p>Prevacuum configuration sterilizers are factory programmed with the following cycles:</p>
<p><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</p>
<p><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</p>
<p><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)</p>
</div>
<div>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</div>
</div>
<p>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.<br />
Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</p>
<p><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisture stable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</p>
<p><u>Utility Requirements</u></p>
<div><b>Steam</b></div>
<div>• 1” NPT</div>
<div>• 50 to 80 psig (3.5 – 5.6 bar) dynamic</div>
<div>• 97% &#8211; 100% vapor quality</div>
<div></div>
<div><b>Drain </b></div>
<div>• 2” ODT drain terminal</div>
<div></div>
<div><b>Electrical &#8211; Controls</b></div>
<div>
<p>• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</p>
<p><b>Electrical–Vacuum Pump</b></p>
<p>• 208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</p>
</div>
<div>• 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</div>
<div><b>Sterilizer Feed Water</b></div>
<div>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</div>
</div>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-160-scientific-steam-sterilizer/">Steris AMSCO Century SG-160 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86352</post-id>	</item>
		<item>
		<title>Steris AMSCO Century SV-160 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sv-160-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:52:07 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86351</guid>

					<description><![CDATA[<div class="Message_messageTextContainer__w64Sc">
<div class="Message_selectableText__SQ8WH">
<div class="Markdown_markdownContainer__Tz3HQ">
<div class="Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9">
<p>The <strong>Steris AMSCO Century SV-160 Scientific Steam Sterilizer</strong> is a high-capacity, pre-vacuum sterilizer engineered for rapid, dependable sterilization of heat- and moisture-stable materials. Featuring a generous chamber size of <strong>26" x 37.5" x 60" (960 Liters)</strong>, it accommodates large loads of liquids, media, glassware, instruments, clothing, and laboratory waste. Equipped with versatile cycle options—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SV-160 ensures thorough sterilization tailored to diverse scientific applications. Its user-friendly interface includes a fluorescent display, impact printer for documentation, and help screens for troubleshooting. Built with a non-lubricated, steam-activated door seal and emergency manual exhaust valve, it guarantees safety and operational efficiency. Optional stainless steel side panels are available for added durability, making the SV-160 an ideal solution for demanding laboratory environments requiring high-volume, repeatable sterilization.</p>
</div>
</div>
</div>
</div>
<div>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-160-scientific-steam-sterilizer/">Steris AMSCO Century SV-160 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SV-160 Scientific Steam Sterilizer</h2>
</div>
<p>Steris SV-160 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The SV-160 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 60″ (960 L) chamber, the SV160 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 60″ chamber (960 Liters)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<p>Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options</p>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8.</div>
<div>
<p>Prevacuum configuration sterilizers are factory programmed with the following cycles:</p>
<p><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</p>
<p><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</p>
<p><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)</p>
</div>
<div>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</div>
</div>
<p>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.<br />
Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</p>
<p><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisture stable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</p>
<p><u>Utility Requirements</u></p>
<div><b>Steam</b></div>
<div>• 1” NPT</div>
<div>• 50 to 80 psig (3.5 – 5.6 bar) dynamic</div>
<div>• 97% &#8211; 100% vapor quality</div>
<div></div>
<div><b>Drain </b></div>
<div>• 2” ODT drain terminal</div>
<div></div>
<div><b>Electrical &#8211; Controls</b></div>
<div>
<p>• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</p>
<p><b>Electrical–Vacuum Pump</b></p>
<p>• 208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</p>
</div>
<div>• 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</div>
<div><b>Sterilizer Feed Water</b></div>
<div>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</div>
</div>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-160-scientific-steam-sterilizer/">Steris AMSCO Century SV-160 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86351</post-id>	</item>
		<item>
		<title>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:44:20 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86350</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</strong> is a high-capacity, gravity-based sterilizer designed for swift, reliable processing of heat- and moisture-stable materials. Featuring a spacious 26" x 37.5" x 48" (767 liters) chamber, it provides ample room to sterilize liquids, media, glassware, instruments, clothing, and laboratory waste efficiently. Equipped with a range of cycle options—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SG-148 offers versatile sterilization tailored to diverse laboratory needs. Its user-friendly features include a fluorescent display, impact printer for cycle documentation, help screens for troubleshooting, and PC connectivity for data management. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it ensures safety and performance. Optional stainless steel side panels are available for added durability, making the SG-148 an excellent choice for demanding scientific applications requiring consistent, high-quality sterilization.</p>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/">Steris AMSCO Century SG-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</h2>
</div>
<div>
<p>Steris SG-148 Scientific Steam Sterilizers are designed for fast, efficient sterilization. The SG-148 gravity sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 48″ (767 Liters) chamber, the SG148 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
</div>
<h2>Features:</h2>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 48″ chamber (767 Liters)</li>
<li>Gravity Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Cabinet Package</li>
<li>Loading Cart</li>
<li>Integral Steam Generator</li>
<li>Water Filtration Options</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<h3>Prevacuum configuration sterilizers are factory programmed with the following cycles:</h3>
<ul>
<li><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</li>
<li><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</li>
<li><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)
<ul>
<li>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</li>
<li>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.</li>
<li>Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
</ul>
</li>
<li><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
<li><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</li>
<li><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</li>
</ul>
</div>
</div>
<h3><u>Utility Requirements:</u></h3>
<ul>
<li><b>Steam</b>
<ul>
<li>1” NPT</li>
<li>50 to 80 psig (3.5 – 5.6 bar) dynamic</li>
<li>97% &#8211; 100% vapor quality</li>
</ul>
</li>
<li><b>Drain</b>
<ul>
<li>2” ODT drain terminal</li>
</ul>
</li>
<li><b>Electrical &#8211; Controls</b>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><b>Electrical–Vacuum Pump</b>
<ul>
<li>208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</li>
<li>480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</li>
</ul>
</li>
<li><b>Sterilizer Feed Water</b>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</li>
</ul>
</li>
</ul>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/">Steris AMSCO Century SG-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86350</post-id>	</item>
		<item>
		<title>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:44:10 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86348</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</strong> is a high-capacity, pre-vacuum sterilizer engineered for rapid and reliable sterilization of heat- and moisture-stable materials. Boasting a spacious <strong>26" x 37.5" x 48" (767 liters) chamber</strong>, it accommodates large loads of liquids, media, glassware, instruments, clothing, and laboratory waste. Equipped with multiple cycles—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SV-148 provides flexible and thorough sterilization tailored to diverse laboratory needs. Its features include a user-friendly fluorescent display, impact printer for cycle documentation, help screens for troubleshooting, and PC connectivity for data management. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it ensures safety and performance. Optional stainless steel side panels are available for added durability. Designed for efficiency and consistency, the SV-148 is ideal for demanding scientific and laboratory applications.</p>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/">Steris AMSCO Century SV-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</h2>
</div>
<div>
<p>Steris SV-148 Scientific Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The SV-148 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 48″ (767 Liters) chamber, the SV148 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
</div>
<h2>Features:</h2>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 48″ chamber (767 Liters)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Cabinet Package</li>
<li>Loading Cart</li>
<li>Integral Steam Generator</li>
<li>Water Filtration Options</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<h3>Prevacuum configuration sterilizers are factory programmed with the following cycles:</h3>
<ul>
<li><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</li>
<li><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</li>
<li><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)
<ul>
<li>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</li>
<li>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.</li>
<li>Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
</ul>
</li>
<li><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
<li><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</li>
<li><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</li>
</ul>
</div>
</div>
<h3><u>Utility Requirements:</u></h3>
<ul>
<li><b>Steam</b>
<ul>
<li>1” NPT</li>
<li>50 to 80 psig (3.5 – 5.6 bar) dynamic</li>
<li>97% &#8211; 100% vapor quality</li>
</ul>
</li>
<li><b>Drain</b>
<ul>
<li>2” ODT drain terminal</li>
</ul>
</li>
<li><b>Electrical &#8211; Controls</b>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><b>Electrical–Vacuum Pump</b>
<ul>
<li>208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</li>
<li>480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</li>
</ul>
</li>
<li><b>Sterilizer Feed Water</b>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</li>
</ul>
</li>
</ul>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/">Steris AMSCO Century SV-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86348</post-id>	</item>
		<item>
		<title>Steris AMSCO SG-136 Scientific Medium Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-sg-136-scientific-medium-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:34:47 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86347</guid>

					<description><![CDATA[<div class="Message_messageTextContainer__w64Sc">
<div class="Message_selectableText__SQ8WH">
<div class="Markdown_markdownContainer__Tz3HQ">
<div class="Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9">
<div class="Message_messageTextContainer__w64Sc">
<div class="Message_selectableText__SQ8WH">
<div class="Markdown_markdownContainer__Tz3HQ">
<div class="Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9">
<p>The <strong>Steris AMSCO SG-136 Scientific Gravity Steam Sterilizer</strong> is a robust and efficient sterilization solution designed for reliable processing of heat- and moisture-stable materials. Featuring a spacious <strong>26" x 37.5" x 36" (575 liters) chamber</strong>, it provides ample capacity to sterilize a wide variety of laboratory equipment, including liquids, media, glassware, instruments, clothing, and waste. Equipped with a pre-vacuum cycle, it also supports gravity, flash, express, leak test, and daily air removal cycles, ensuring versatile and thorough sterilization. The sterilizer features a user-friendly fluorescent display, impact printer for cycle documentation, and help screens for troubleshooting. Its non-lubricated, steam-activated door seal and emergency manual exhaust valve enhance safety and performance. Additionally, the SG-136 supports PC connectivity with various communication interfaces and offers optional stainless steel side panels for added durability. Designed for fast, repeatable results, this sterilizer meets the demanding needs of scientific and laboratory applications.</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="Message_messageMetadataContainer__nBPq7">[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sg-136-scientific-medium-steam-sterilizer/">Steris AMSCO SG-136 Scientific Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO SG-136 Scientific Medium Steam Sterilizer</h2>
</div>
<p>Steris AMSCSO SG-136 Scientific Gravity Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The SG-136 gravity sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26&#8243; x 37.5&#8243; x 36&#8243; (575 Liters) chamber, the SG-136 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26&#8243; x 37.5&#8243; x 36&#8243; chamber (575 L)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<p><strong>Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options</strong></p>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<div>
<div>
<div>
<p>Interior Chamber Dimensions:</p>
<ul>
<li>26&#8243; x 37.5&#8243; x 36&#8243; (660 x 950 x 910 mm)</li>
</ul>
<p>Vacuum Pump Electric Service:</p>
</div>
</div>
</div>
<ul>
<li>208/240 VAC, 60 Hz, 3-Phase, 6A per phase</li>
<li>480 VAC, 60 Hz, 3-Phase, 3A per phase</li>
</ul>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<p>Prevacuum configuration sterilizers are factory programmed with the following cycles:</p>
<p><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</p>
<p><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</p>
<p><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)</p>
</div>
<div>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</div>
</div>
<p>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.<br />
Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</p>
<p><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</p>
<p><u>Utility Requirements</u></p>
<p><b>Steam</b></p>
<div>• 1” NPT</div>
<div>• 50 to 80 psig (3.5 – 5.6 bar) dynamic</div>
<div>• 97% &#8211; 100% vapor quality</div>
<div></div>
<div><b>Drain </b></div>
<div>• 2” ODT drain terminal</div>
<div></div>
<div><b>Electrical &#8211; Controls</b></div>
<div>
<p>• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</p>
<p><b>Electrical–Vacuum Pump</b></p>
<p>• 208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</p>
</div>
<div>• 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</div>
<div><b>Sterilizer Feed Water</b></div>
<div>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</div>
</div>
</td>
</tr>
</tbody>
</table>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sg-136-scientific-medium-steam-sterilizer/">Steris AMSCO SG-136 Scientific Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86347</post-id>	</item>
		<item>
		<title>Steris AMSCO SV-136 Scientific Medium Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-sv-136-scientific-medium-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:34:07 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86345</guid>

					<description><![CDATA[<div class="Message_messageTextContainer__w64Sc">
<div class="Message_selectableText__SQ8WH">
<div class="Markdown_markdownContainer__Tz3HQ">
<div class="Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9">
<p>The <strong>Steris AMSCO SV-136 Scientific Medium Steam Sterilizer</strong> is a high-capacity, pre-vacuum sterilizer designed for fast, reliable sterilization of heat- and moisture-stable materials. Featuring a spacious 26" x 37.5" x 36" (575 liters) chamber, it provides ample room to sterilize all your laboratory equipment efficiently. Equipped with a user-friendly fluorescent display, ink-on-paper impact printer, and help screens for troubleshooting, it ensures ease of operation and thorough documentation. The SV-136 supports multiple cycles, including pre-vacuum, gravity, flash, express, leak test, and daily air removal, making it versatile for various sterilization needs. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it guarantees safety and performance. Optional stainless steel side panels are available for added durability. Designed for high-quality, repeatable performance, the SV-136 is ideal for sterilizing liquids, media, glassware, instruments, clothing, and laboratory waste in demanding scientific environments.</p>
</div>
</div>
</div>
</div>
<div class="Message_messageMetadataContainer__nBPq7">[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-136-scientific-medium-steam-sterilizer/">Steris AMSCO SV-136 Scientific Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO SV-136 Scientific Medium Steam Sterilizer</h2>
</div>
<p>Steris AMSCSO SV-136 Scientific Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The SV-136 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26&#8243; x 37.5&#8243; x 36&#8243; (575 Liters) chamber, the SV-136 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26&#8243; x 37.5&#8243; x 36&#8243; chamber (575 L)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<p><strong>Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options</strong></p>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<div>
<div>
<div>
<p>Interior Chamber Dimensions:</p>
<ul>
<li>26&#8243; x 37.5&#8243; x 36&#8243; (660 x 950 x 910 mm)</li>
</ul>
<p>Vacuum Pump Electric Service:</p>
</div>
</div>
</div>
<ul>
<li>208/240 VAC, 60 Hz, 3-Phase, 6A per phase</li>
<li>480 VAC, 60 Hz, 3-Phase, 3A per phase</li>
</ul>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<p>Prevacuum configuration sterilizers are factory programmed with the following cycles:</p>
<p><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</p>
<p><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</p>
<p><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)</p>
</div>
<div>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</div>
</div>
<p>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.<br />
Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</p>
<p><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</p>
<p><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</p>
<p><u>Utility Requirements</u></p>
<p><b>Steam</b></p>
<div>• 1” NPT</div>
<div>• 50 to 80 psig (3.5 – 5.6 bar) dynamic</div>
<div>• 97% &#8211; 100% vapor quality</div>
<div></div>
<div><b>Drain </b></div>
<div>• 2” ODT drain terminal</div>
<div></div>
<div><b>Electrical &#8211; Controls</b></div>
<div>
<p>• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</p>
<p><b>Electrical–Vacuum Pump</b></p>
<p>• 208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</p>
</div>
<div>• 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</div>
<div><b>Sterilizer Feed Water</b></div>
<div>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</div>
</div>
</td>
</tr>
</tbody>
</table>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-136-scientific-medium-steam-sterilizer/">Steris AMSCO SV-136 Scientific Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86345</post-id>	</item>
		<item>
		<title>Steris AMSCO Century Small Sterilizer &#8211; Steris SV-120 Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-sv-120-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:22:53 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86344</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO SV-120 Small Steam Sterilizer</strong> is a high-performance, pre-vacuum sterilizer designed for reliable sterilization of nonporous, heat- and moisture-stable materials. Featuring a spacious <strong>20" x 20" x 38" (250 liters / 66 gallons) chamber</strong> made from durable 316L stainless steel, it is ideal for sterilizing liquids, media, glassware, instruments, clothing, and laboratory waste. Equipped with vertical doors with glass panels, an ALUS chamber rail for racks, and a 6.5-inch high-resolution color touch screen, the sterilizer offers intuitive operation and comprehensive cycle tracking via external USB, PDF reports, and a built-in matrix printer. Additional features include independent temperature probes, pneumatic valves, safety controls, and a water-saving system for the vacuum pump. Certified for safety and performance, the SV-120 ensures consistent, repeatable sterilization for demanding laboratory and medical applications.</p>
<p>[vc_btn title="<strong>Steris Amsco Century Small Scientific Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-sv-120-steam-sterilizer/">Steris AMSCO Century Small Sterilizer &#8211; Steris SV-120 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Steris AMSCO Century Small Sterilizer &#8211; Steris SV-120 Steam Sterilizer</h2>
<p>Steris AMSCO SV-120 Prevacuum Steam Sterilizer (20&#8243; x 20&#8243; x 38&#8243; Chamber, 250 Liters / 66 gallons) is designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Chamber material and pipe work 316L stainless steel</li>
<li>Fully jacketed chamber</li>
<li>Vertical opening doors with glass panel</li>
<li>ALUS chamber rail for racks</li>
<li>6.5” (165 mm) high resolution color touch screen</li>
<li>Interface to tracking system XLM and PDF format</li>
<li>External USB connection for data download (on loading side)</li>
<li>Matrix printer on loading side with A4 print out capability</li>
<li>Additional touch screen provided on the unloading side</li>
<li>Independent temperature probe (chamber)</li>
<li>Pneumatic valves</li>
<li>Air filter</li>
<li>Pressure gauges for jacket, chamber, steam generator (loading side), chamber (unloading side)</li>
<li>Water level gauge for steam generator</li>
<li>Safety temperature switch for door opening</li>
<li>Acoustic signal for end cycle and alarms</li>
<li>Programmable timer start for test cycles</li>
<li>Potential free outputs for critical alarms</li>
<li>Sanitary piping with Tri-clamp</li>
<li>Water Saving System For Vacuum Pump</li>
<li>Separate water feed line for steam generator and vacuum pump</li>
<li>Drain discharge cool down</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf" title="" target="_blank"><strong>Steris Amsco Century Small Scientific Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-sv-120-steam-sterilizer/">Steris AMSCO Century Small Sterilizer &#8211; Steris SV-120 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86344</post-id>	</item>
		<item>
		<title>Steris AMSCO Century Small Sterilizer &#8211; Steris G-120 Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-g-120-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:22:34 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86323</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO G-120 Small Steam Sterilizer</strong> (also known as the G-120 Steris Sterilizer) is a high-quality, gravity-displacement steam sterilizer designed for reliable sterilization of nonporous, heat- and moisture-stable materials. Featuring a spacious <strong>20" x 20" x 38" (250 liters / 66 gallons) chamber</strong>, it is ideal for laboratory and medical applications involving liquids, media, glassware, instruments, clothing, and waste. Constructed with 316L stainless steel for durability, the sterilizer includes a fully jacketed chamber, vertical doors with glass panels, and an ALUS chamber rail for rack support. Equipped with a 6.5-inch high-resolution color touch screen, external USB data download, and a matrix printer, it offers comprehensive cycle tracking and documentation. Additional features include independent temperature probes, pneumatic valves, safety controls, and a water-saving system for the vacuum pump. Certified for safety and performance, the G-120 provides consistent, repeatable sterilization suitable for demanding laboratory environments.</p>
<p>[vc_btn title="<strong>Steris Amsco Century Small Scientific Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-g-120-steam-sterilizer/">Steris AMSCO Century Small Sterilizer &#8211; Steris G-120 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Steris AMSCO Century Small Sterilizer &#8211; Steris G-120 Steam Sterilizer</h2>
<p>Steris AMSCO G-120 Gravity Steam Sterilizer (20&#8243; x 20&#8243; x 38&#8243; Chamber, 250 Liters / 66 gallons) is designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Chamber material and pipe work 316L stainless steel</li>
<li>Fully jacketed chamber</li>
<li>Vertical opening doors with glass panel</li>
<li>ALUS chamber rail for racks</li>
<li>6.5” (165 mm) high resolution color touch screen</li>
<li>Interface to tracking system XLM and PDF format</li>
<li>External USB connection for data download (on loading side)</li>
<li>Matrix printer on loading side with A4 print out capability</li>
<li>Additional touch screen provided on the unloading side</li>
<li>Independent temperature probe (chamber)</li>
<li>Pneumatic valves</li>
<li>Air filter</li>
<li>Pressure gauges for jacket, chamber, steam generator (loading side), chamber (unloading side)</li>
<li>Water level gauge for steam generator</li>
<li>Safety temperature switch for door opening</li>
<li>Acoustic signal for end cycle and alarms</li>
<li>Programmable timer start for test cycles</li>
<li>Potential free outputs for critical alarms</li>
<li>Sanitary piping with Tri-clamp</li>
<li>Water Saving System For Vacuum Pump</li>
<li>Separate water feed line for steam generator and vacuum pump</li>
<li>Drain discharge cool down</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf" title="" target="_blank"><strong>Steris Amsco Century Small Scientific Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-small-sterilizer-steris-g-120-steam-sterilizer/">Steris AMSCO Century Small Sterilizer &#8211; Steris G-120 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86323</post-id>	</item>
		<item>
		<title>Steris AMSCO SV-116 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:11:58 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86343</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO SV-116 Scientific Steam Sterilizer</strong> is a high-performance, pre-vacuum sterilizer designed for reliable sterilization of nonporous, heat- and moisture-stable laboratory items. With a spacious <strong>16" x 16" x 26" (109 liters)</strong> chamber, it accommodates a variety of laboratory applications, including sterilization of liquids, media, glassware, instruments, clothing, and waste. The unit features a user-friendly fluorescent display, an impact printer for cycle documentation, and a touch screen interface for easy operation and troubleshooting. Built as a freestanding vertical door model, it includes a rack and two shelves, an emergency manual exhaust valve, and a non-lubricated, steam-activated door seal for efficient performance. Certified to UL, CSA, and ASME standards, with a maximum operating temperature of 250º to 270ºF, the SV-116 offers fast, efficient sterilization with high accountability, making it ideal for demanding laboratory environments.</p>
<p>[vc_btn title="<strong>Steris Amsco Century Small Scientific Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/">Steris AMSCO SV-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Steris AMSCO SV-116 Scientific Steam Sterilizer</h3>
<p>Steris AMSCO SV-116 Pre-vacuum Steam Sterilizer is designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>16″ x 16″ x 26″ chamber (109 Liters)</li>
<li>Rack and 2 shelves</li>
<li>Freestanding unit</li>
<li>Vertical Door</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
</ul>
<h3>Specifications:</h3>
<ul>
<li>Chamber Size: 16&#8243; x 16&#8243; x 26” (109 Liters)</li>
<li>Overall Exterior Dimensions (including door lock-wheel): 74.5&#8243;H x 30&#8243;W x 35.75&#8243;D (with door closed)</li>
<li>Operating Temperature: 250º to 270º</li>
<li>One (1) Rack, Two (2) Shelves</li>
<li>Touch Screen Display</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf" title="" target="_blank"><strong>Steris Amsco Century Small Scientific Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/">Steris AMSCO SV-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86343</post-id>	</item>
		<item>
		<title>Steris AMSCO 630LS Medium Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-630ls-medium-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Thu, 15 Jan 2026 21:40:50 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86336</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO 630LS Medium Sterilizer</strong> is a versatile and energy-efficient steam sterilizer designed for scientific and healthcare applications. It offers a spacious chamber, ideal for larger loads, and supports a range of sterilization cycles including pre-vacuum, gravity, liquid, leak test, and daily air removal (Bowie-Dick), all configurable to meet specific processing requirements. The pre-vacuum configuration ensures rapid, thorough sterilization of heat- and moisture-stable materials, making it perfect for laboratory and medical environments. With pre-programmed standardized cycles that can be customized, the 630LS enhances operational efficiency, while its advanced STERI-Green® and STERI-Green Plus® water and energy conservation systems help reduce resource consumption. User-friendly controls and an intuitive interface make cycle programming straightforward, ensuring reliable sterilization with minimal effort. Designed for speed, sustainability, and flexibility, the AMSCO 630LS is an excellent choice for demanding scientific and clinical sterilization needs.</p>
<p>[vc_btn title="Steris AMSCO 630LS Data Sheet" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-AMSCO-LS-Series-Medium-Steam-Sterilizers-630LS-Data-Sheet.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-630ls-medium-steam-sterilizer/">Steris AMSCO 630LS Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<h3>Steris AMSCO 630LS Medium Sterilizer</h3>
</div>
<p>The AMSCO™ 630LS Medium Steam Sterilizer provides convenient, energy-efficient sterilization for heat and moisture-stable materials, ideal for scientific applications. Ensure optimal results with a wide range of versatile cycle options and flexible chamber sizes, allowing for larger loading patterns. Save time with user-friendly controls and enhanced connectivity with remote monitoring. The AMSCO 630LS Laboratory Medium Steam Sterilizer is offered in a prevacuum configuration and is designed for fast, efficient sterilization of heat- and moisture-stable materials in scientific applications. The prevacuum configuration sterilizer is equipped with prevacuum, gravity, liquid, leak test, and daily air removal (Bowie-Dick) test cycles.</p>
<ul>
<li><strong>Flexibility in Every Cycle: </strong>Pre-programmed with standardized cycles, including pre-vacuum, liquid, gravity, leak test and daily air removal cycles, each of which can be adjusted to meet your specific processing needs, enhancing efficiency with every use.</li>
<li><strong>Improved Sustainability Efforts:</strong> STERI-Green® and STERI-Green Plus® water conservations systems significantly reduced water consumption and energy use in each cycle.</li>
<li><strong>User-Friendly Operation:</strong> The simple control system paired with an intuitive interface allows for efficient cycle programming and operation, ensuring effective sterilization takes place to meet your unique needs.</li>
</ul>
<div class="column">
<h3>Features:</h3>
<p><strong>Allen-Bradley MicroLogix™ Control System with enhanced functionality and user-friendly Allen-Bradley PanelView Plus™ 7 700 interface screen.*</strong></p>
<ul>
<li>Touch-sensitive screen with 18-bit color graphic display</li>
<li>Display features 640 x 840 resolution color-active matrix</li>
<li>Display is designed with emphasis on human factors and user recognizable symbols.</li>
</ul>
<p><strong>Hinged door with fast operating, low-effort door lock mechanism. Manual door handle lock lever requires a single 30° handle movement to lock or unlock.</strong></p>
<p><strong>Cycle Programming and Flash Memory</strong></p>
<ul>
<li>20 cycles may be individually selected and program</li>
<li>Help screens for control operation</li>
<li>Program permanently stored in flash memory</li>
<li>Variables permanently stored in flash memory</li>
</ul>
</div>
</div>
</div>
<p><strong>Processing Cycles:</strong><br />
This scientific sterilizer is factory programmed with the following cycles:</p>
<ul>
<li><strong>Prevacuum Cycle:</strong> for efficient, high-volume sterilization of porous, heat- and moisture-stable materials in the temperature range of 121°C to 137°C. The prevacuum cycle uses a mechanical air evacuation system.</li>
<li><strong>Gravity Cycle:</strong> for the sterilization of heat- and moisture-stable goods in the range of 100°C to 137°C), and decontamination of bagged basic laboratory wastes. The gravity cycle uses the gravity air-displacement principle.</li>
<li><strong>Liquid Cycle:</strong> for sterilization of liquids and media in vented borosilicate glass or metal containers in the range of 100°C to 123°C. Liquid cycle uses the optimal solution cooling feature during the exhaust (cooling) phase to control the exhaust rate.</li>
<li><strong>USP 660 Cycle</strong> (standard) developed to assist meeting the requirements of USP 660 sterilization test cycle for glassware. Load probe option is recommended when using the USP cycle.</li>
<li><strong>Continuous Cycle</strong> (standard) This cycle allows for up to 9,999 cycles to be run consecutively without the need of an operator. Cycle parameters can be set, along with the amount of time to lapse in between cycles.</li>
<li><strong>Waste Bag Cycle</strong> (standard) comes configured with cycle parameters shown to be effective when processing lab waste in autoclavable bags. Through air removal assistance and a controlled exhaust, the internal temperature is increased more effectively and faster, while minimizing boil over of any liquids present. Parameters may need to be adjusted based on specific loads. Bags should not be completely sealed.</li>
<li><strong>ATF 1 and ATF 2 Cycles</strong> (Alternating Tangential Flow) are designed to sterilize the XCell™ ATF system. These can be used for other purposes that require rates and hold times in the pre-conditioning pulses.</li>
<li><strong>Healthcare Cycles</strong> &#8211; The LS Series sterilizers can be programmed to reproduce cycles that are used for healthcare applications, however, <strong>these sterilizers do not have FDA clearance and cannot be used for patient treatment applications.</strong></li>
</ul>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 3">
<div class="layoutArea">
<div class="column">
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-AMSCO-LS-Series-Medium-Steam-Sterilizers-630LS-Data-Sheet.pdf" title="" target="_blank">Steris AMSCO 630LS Data Sheet</a></div>
</div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-630ls-medium-steam-sterilizer/">Steris AMSCO 630LS Medium Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86336</post-id>	</item>
	</channel>
</rss>
