<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Flo-Gard 6201 &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/product-tag/flo-gard-6201/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Wed, 08 Jul 2026 20:29:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>Flo-Gard 6201 &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>Baxter Flo-Gard 6201 &#8211; RENTAL</title>
		<link>https://auxomedical.com/products/baxter-flo-gard-6201-rental/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 01 May 2020 15:20:00 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=11281</guid>

					<description><![CDATA[<p>The Flo-Gard® 6201 Volumetric Infusion Pump from Baxter® can deliver a wide variety of fluids over a broad range of infusion rates. Uses only standard Baxter®solution administration sets. Configurable settings allow the pump to be custom-tailored to best suit the hospital’s needs. Pumps a wide variety of fluids, including blood and fat emulsions. Occlusion sensors detect both upstream and downstream restrictions.</p>
<p>The Programmed Delivery Profile (PDP) enables manual programming or ramped calculation of up to 10 sequential infusion programs for situations where multiple flow raters are indicated. Slide clamp loading option provides flow shutoff when I.V. set is removed from the pump. Locking control panel helps prevent patient tampering. Volume-Time programming automatically calculates flow rate. An automatic self-test routine checks for proper function before use. Five-hour memory retains infusion data after power-off.<br />
[vc_btn title="Download Brochure" style="flat" shape="square" link="url: /wp-content/uploads/2016/11/Baxter-Flo-Gard-6201-Infusion-Pump-Auxo-Brochure.pdf &#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/baxter-flo-gard-6201-rental/">Baxter Flo-Gard 6201 &#8211; RENTAL</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Flo-Gard® 6201 Volumetric Infusion Pump from Baxter® can deliver a wide variety of fluids over a broad range of infusion rates. Uses only standard Baxter®solution administration sets. Configurable settings allow the pump to be custom-tailored to best suit the hospital’s needs. Pumps a wide variety of fluids, including blood and fat emulsions. Occlusion sensors detect both upstream and downstream restrictions.</p>
<p>The Programmed Delivery Profile (PDP) enables manual programming or ramped calculation of up to 10 sequential infusion programs for situations where multiple flow raters are indicated. Slide clamp loading option provides flow shutoff when I.V. set is removed from the pump. Locking control panel helps prevent patient tampering. Volume-Time programming automatically calculates flow rate. An automatic self-test routine checks for proper function before use. Five-hour memory retains infusion data after power-off.</p>
<p>&nbsp;</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2016/11/Baxter-Flo-Gard-6201-Infusion-Pump-Auxo-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/baxter-flo-gard-6201-rental/">Baxter Flo-Gard 6201 &#8211; RENTAL</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">11281</post-id>	</item>
		<item>
		<title>Baxter Flo-Gard 6201</title>
		<link>https://auxomedical.com/products/baxter-flo-gard-6201/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 25 Nov 2016 10:59:05 +0000</pubDate>
				<guid isPermaLink="false">http://auxomedical.jonaswebsitedesign.com/?post_type=product&#038;p=2196</guid>

					<description><![CDATA[<p>The <strong>Baxter Flo-Gard 6201 Volumetric Infusion Pump</strong> is a dependable, high-performance IV pump designed to deliver precise fluid administration across a wide range of infusion rates. Ideal for hospitals, surgical centers, and clinical settings, this single-channel infusion pump offers enhanced safety features such as a Flow Check Occlusion Alarm with in-line resistance monitoring, automatic restart after occlusion clearance, and a slide clamp option to prevent inadvertent gravity free flow. The Flo-Gard 6201 automatically calculates flow rates once volume and time are entered, supports programmable delivery profiles with up to 10 steps for customized infusion ramping and tapering, and allows incremental flow rate adjustments from 0.1 mL/hr up to 1,999 mL/hr. With automatic piggyback capability for secondary medications, front panel lock-out protection, and compatibility with Baxter standard IV administration sets to reduce waste and costs, this volumetric infusion pump combines versatility, convenience, and reliability. Compact and portable at 11.4” high, 8” wide, and 11.6 lbs, it operates on a 12-volt sealed lead-acid battery, making the Baxter Flo-Gard 6201 a trusted solution for accurate, controlled IV therapy.</p>
<p>[vc_btn title="Download Brochure" style="flat" shape="square" link="url: /wp-content/uploads/2016/11/Baxter-Flo-Gard-6201-Infusion-Pump-Auxo-Brochure.pdf &#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p><strong>Warranty: 6 Months</strong></p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/baxter-flo-gard-6201/">Baxter Flo-Gard 6201</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Baxter Flo-Gard 6201</h2>
<p>The Flo-Gard 6201 Volumetric Infusion Pump from Baxter can deliver a wide variety of fluids over a broad range of infusion rate. Enhanced safety, greater convenience and versatility, and Baxter standard IV administration sets that eliminate the need for costly disposable sets and reduce the potential for waste make the Flo-Gard 6201 the perfect infusion pump.</p>
<h3>Features:</h3>
<ul>
<li>Flow Check Occlusion Alarm-an in-line resistance display of incremental back pressure</li>
<li>Flow Rate Calculation is automatic after volume and time are selected</li>
<li>Slide Clamp Option offers an additional step to protect against inadvertent gravity free flow</li>
<li>Front Panel Lock-out protects against tampering</li>
<li>Programmed Delivery Profile allows up to 10 steps, individualizing control of infusion ramping and tapering</li>
<li>Incremental Flow Rate can deliver 1-99.9 mL /hr in increments of 0.1 mL /hr</li>
<li>Automatic Restart once occlusion clears</li>
<li>Automatic Piggybacking of secondary medications</li>
<li>Channels: Single</li>
<li>Range of Flow: Rate 1 &#8211; 99.9 mL/hr in 0.1 mL/hr increments and 1 &#8211; 1,999 ml/hr in 1 mL/hr increments</li>
<li>Maximum VTBI: 1 &#8211; 9,999 mL</li>
<li>Alarm Intervals: 1-7 seconds</li>
<li>Battery/Time: 12 volt, 2.0 ampere, sealed lead acid</li>
<li>Height: 11.4”</li>
<li>Width: 8”</li>
<li>Weight: 11.6 lbs</li>
</ul>
<p><strong>6 Month Warranty</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2016/11/Baxter-Flo-Gard-6201-Infusion-Pump-Auxo-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/baxter-flo-gard-6201/">Baxter Flo-Gard 6201</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2196</post-id>	</item>