<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>FujiFilm &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/product-tag/fujifilm/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Tue, 05 May 2026 19:28:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>FujiFilm &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>Fuji Carbon Fiber Top Adjustable Height X-ray Table (P/N: 800051360)</title>
		<link>https://auxomedical.com/products/fuji-carbon-fiber-top-adjustable-height-x-ray-table-p-n-800051360/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 05 May 2026 19:25:10 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87108</guid>

					<description><![CDATA[<div>
<div>The <strong>Fuji Carbon Fiber Top Adjustable Height X-ray Table (Part Number: 800051360)</strong> combines advanced design with high-performance features to support demanding radiographic procedures. Its carbon fiber tabletop provides low attenuation, ensuring high-contrast images at minimal patient dose, making it ideal for high-volume imaging environments. Built with a simple and durable ergonomic structure, the table features a 4-way floating surface that operates without power, alongside four lockable swivel wheels for effortless, secure mobility. Equipped with electromagnetic and mechanical brakes for safety, the table can be precisely positioned via foot pedals controlling transversal, longitudinal, and height adjustments. Arranged with auto-positioning, preset heights can be conveniently configured during installation, while optional fixation and anti-turnover pins enhance patient safety. The table is powered by four rechargeable batteries lasting up to 16 hours, recharged within a maximum of 12 hours—rechargeable even while plugged into a standard 110 VAC outlet. With a maximum patient load of 551 lbs., dimensions of 92.7” x 25.6”, and a large radiolucent surface (82.7” x 18.1”), this versatile, robust X-ray table ensures reliable, high-quality patient positioning in busy imaging departments.</div>
</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-carbon-fiber-top-adjustable-height-x-ray-table-p-n-800051360/">Fuji Carbon Fiber Top Adjustable Height X-ray Table (P/N: 800051360)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji Carbon Fiber Top Adjustable Height X-ray Table</h2>
<p>Part Number: 800051360</p>
<h3>Features:</h3>
<ul>
<li>Carbon fiber tabletop &#8211; low attenuation for high contrast radiographic images with minimal patient dose.</li>
<li>Simple ergonomic and robust design to withstand high volume imaging</li>
<li>Ergonomic handles for safe, easy travel and patient support</li>
<li>4-way floating table top &#8211; functions without power</li>
<li>4 locking swivel wheels &#8211; for safe, easy travel maneuverability and secure locked use.</li>
<li>Electromagnetic and mechanical brakes when power is OFF.</li>
<li>Foot pedals &#8211; control tabletop movements (transversal, longitudinal, raising and lowering).</li>
<li>Emergency OFF safety switch at table side</li>
<li>Auto-positioning &#8211; site preferred preset height can be configured during installation</li>
<li>Floor pins &#8211; prevent table from tipping over and mark repeatable preferred floor location.</li>
<li>4 rechargeable batteries &#8211; built into the table base.</li>
<li>3-color battery level indicator &#8211; at controls with audible warning when batteries reach lowest discharge level.</li>
<li>Battery operation &#8211; lasts up to 16 hours</li>
<li>Plug in use &#8211; table can be operated while plugged into standard 110 VAC outlet</li>
<li>Recharging time &#8211; maximum, 12 hours</li>
</ul>
<h3>Specs:</h3>
<ul>
<li>Patient maximun load 551 lbs. (250 Kg)</li>
<li>Dimensions (L x W) 92.7 x 25.6” (235.5 x 65 cm)</li>
<li>Tabletop travels:
<ul>
<li>Longitudinal 38.6”, ±0.4” (98.2 cm, ±1 cm )</li>
<li>Transversal 8.27”, ±0.4” (21 cm, ±1 cm)</li>
<li>Vertical 157.5”,23.6” (400 cm, ±6 cm)</li>
<li>Maximum height 39.3”, ±1.18” (100 cm, ±3 cm)</li>
<li>Minimum height 23.6”, ±1.18” (60 cm, ±3 cm)</li>
</ul>
</li>
<li>Tabletop radiolucent area: (W x deep) 82.7”x18.1” (210&#215;46 cm)</li>
<li>Tabletop attenuation &lt; 1,2 mm equival. Al. a 100 KV</li>
<li>Tabletop composition Laminated or carbon fiber</li>
<li>Control pedals 4</li>
<li>Anti-turnover pins 2, optional</li>
<li>Table fixation pins and housings Optional</li>
<li>Rechargeable batteries 4</li>
<li>Battery autonomy 16H with a ratio of 1% elevating movements or ±100 vertical movements</li>
<li>Recharging time 12H Maximum. Recharging is activated when the equipment is plugged in</li>
</ul>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-carbon-fiber-top-adjustable-height-x-ray-table-p-n-800051360/">Fuji Carbon Fiber Top Adjustable Height X-ray Table (P/N: 800051360)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87108</post-id>	</item>
		<item>
		<title>Fuji Laminate Top Adjustable Height X-ray Table (P/N: 800051359)</title>
		<link>https://auxomedical.com/products/fuji-laminate-top-adjustable-height-x-ray-table-p-n-800051359/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 05 May 2026 19:24:41 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87107</guid>

					<description><![CDATA[<div>
<div>The <strong>Fuji Laminate Top Adjustable Height X-ray Table (Part Number: 800051359)</strong> combines ergonomic design, durability, and versatile functionality to support high-volume imaging environments. Built with a simple, robust structure, it features a 4-way floating tabletop that operates without power, along with 4 lockable swivel wheels for safe and easy mobility, complemented by electromagnetic and mechanical brakes for secure positioning even when power is off. The table is equipped with convenient foot pedals for transverse, longitudinal, and height adjustments, and an emergency safety switch at the side ensures quick shutdown if needed. Its auto-positioning system allows preset height configurations for efficiency, while four rechargeable batteries provide up to 16 hours of cordless operation, with a maximum recharge time of 12 hours—rechargeable while plugged into standard 110 VAC outlets. Designed to withstand up to 551 lbs., the table’s dimensions (92.7” x 25.6”) include a large, radiolucent laminated or carbon fiber surface (82.7” x 18.1”) with minimal attenuation, making it ideal for a wide range of diagnostic procedures. Complete with optional fixation pins and anti-turnover devices, this adjustable-height table ensures reliable, safe, and efficient patient positioning for demanding clinical settings.</div>
</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-laminate-top-adjustable-height-x-ray-table-p-n-800051359/">Fuji Laminate Top Adjustable Height X-ray Table (P/N: 800051359)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji Laminate Top Adjustable Height X-ray Table</h2>
<p>Part Number: 800051359</p>
<h3>Features:</h3>
<ul>
<li>Simple ergonomic and robust design to withstand high volume imaging</li>
<li>Ergonomic handles for safe, easy travel and patient support</li>
<li>4-way floating table top &#8211; functions without power</li>
<li>4 locking swivel wheels &#8211; for safe, easy travel maneuverability and secure locked use.</li>
<li>Electromagnetic and mechanical brakes when power is OFF.</li>
<li>Foot pedals &#8211; control tabletop movements (transversal, longitudinal, raising and lowering).</li>
<li>Emergency OFF safety switch at table side</li>
<li>Auto-positioning &#8211; site preferred preset height can be configured during installation</li>
<li>Floor pins &#8211; prevent table from tipping over and mark repeatable preferred floor location.</li>
<li>4 rechargeable batteries &#8211; built into the table base.</li>
<li>3-color battery level indicator &#8211; at controls with audible warning when batteries reach lowest discharge level.</li>
<li>Battery operation &#8211; lasts up to 16 hours</li>
<li>Plug in use &#8211; table can be operated while plugged into standard 110 VAC outlet</li>
<li>Recharging time &#8211; maximum, 12 hours</li>
</ul>
<h3>Specs:</h3>
<ul>
<li>Patient maximun load 551 lbs. (250 Kg)</li>
<li>Dimensions (L x W) 92.7 x 25.6” (235.5 x 65 cm)</li>
<li>Tabletop travels:
<ul>
<li>Longitudinal 38.6”, ±0.4” (98.2 cm, ±1 cm )</li>
<li>Transversal 8.27”, ±0.4” (21 cm, ±1 cm)</li>
<li>Vertical 157.5”,23.6” (400 cm, ±6 cm)</li>
<li>Maximum height 39.3”, ±1.18” (100 cm, ±3 cm)</li>
<li>Minimum height 23.6”, ±1.18” (60 cm, ±3 cm)</li>
</ul>
</li>
<li>Tabletop radiolucent area: (W x deep) 82.7”x18.1” (210&#215;46 cm)</li>
<li>Tabletop attenuation &lt; 1,2 mm equival. Al. a 100 KV</li>
<li>Tabletop composition Laminated or carbon fiber</li>
<li>Control pedals 4</li>
<li>Anti-turnover pins 2, optional</li>
<li>Table fixation pins and housings Optional</li>
<li>Rechargeable batteries 4</li>
<li>Battery autonomy 16H with a ratio of 1% elevating movements or ±100 vertical movements Recharging time 12H Maximum. Recharging is activated when the equipment is plugged in.</li>
</ul>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-laminate-top-adjustable-height-x-ray-table-p-n-800051359/">Fuji Laminate Top Adjustable Height X-ray Table (P/N: 800051359)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87107</post-id>	</item>
		<item>
		<title>Fuji Carbon Fiber Top Fixed Height X-ray Table (P/N: 800051331)</title>
		<link>https://auxomedical.com/products/fuji-carbon-fiber-top-fixed-height-x-ray-table-p-n-800051331/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 04 May 2026 20:07:18 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87103</guid>

					<description><![CDATA[<div><strong>The Fuji Carbon Fiber Top Fixed Height X-ray Table (Part Number: 800051331)</strong> is a lightweight, durable imaging platform designed for high-performance radiography. Its carbon fiber top measures 78.7 inches in length, 25.6 inches in width, and 27.6 inches in height, providing a strong, corrosion-resistant surface suitable for demanding clinical environments. Weighing only 66 lbs, this table facilitates easy positioning and transport, while supporting patients weighing up to 441 lbs (200 kg). The open area between the wheelbase measures 76.3 x 25.6 inches, enabling efficient patient transfer and positioning for a variety of imaging procedures, making it an ideal addition to busy radiology departments.</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-carbon-fiber-top-fixed-height-x-ray-table-p-n-800051331/">Fuji Carbon Fiber Top Fixed Height X-ray Table (P/N: 800051331)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji Carbon Fiber Top Fixed Height X-ray Table</h2>
<p>Carbon Fiber Top</p>
<p>Part Number: 800051331</p>
<p>Size: 78.7 x 25.6 x 27.6”, 66 lb carbon</p>
<p>Open area between wheel base:<br />
76.3 x 25.6&#8243; carbon</p>
<p>Patient capacity 441 lbs. (200 kg)</p>
<p>X-ray Pictured Not Included</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-carbon-fiber-top-fixed-height-x-ray-table-p-n-800051331/">Fuji Carbon Fiber Top Fixed Height X-ray Table (P/N: 800051331)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87103</post-id>	</item>
		<item>
		<title>Fuji Laminate Top Fixed Height X-ray Table (P/N: 800051332)</title>
		<link>https://auxomedical.com/products/fuji-laminate-top-fixed-height-x-ray-table-p-n-800051332/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 04 May 2026 19:49:17 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87099</guid>

					<description><![CDATA[<div>The <strong>Fuji Laminate Top Fixed Height X-ray Table (Part Number: 800051332)</strong> offers a durable, sturdy platform designed to support patient imaging needs with a fixed height configuration. Crafted with a laminated carbon surface, it accommodates patients weighing up to 551 lbs (250 kg), ensuring reliable performance across a variety of clinical settings. The table measures 78.7 inches in length, 25.6 inches in width, and 27.6 inches in height, with an open area between the wheelbase of 74 x 25.6 inches to facilitate easy patient transfer and positioning. Weighing approximately 101.4 lbs, this fixed-height laminate table provides a solid, corrosion-resistant surface ideal for consistent, high-quality radiographic procedures.</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-laminate-top-fixed-height-x-ray-table-p-n-800051332/">Fuji Laminate Top Fixed Height X-ray Table (P/N: 800051332)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji Laminate Top Fixed Height X-ray Table</h2>
<p>Fixed Height Laminated</p>
<p>Part Number: 800051332</p>
<p>551 lb (250 kg) Patient capacity laminate carbon</p>
<p>78.7L x 25.6W x 27.6&#8243;H / Wt 101.4 lb laminate,</p>
<p>Open area between wheel base:<br />
74 x 25.6&#8243; laminate</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/05/Mobile-Radiographic-Tables-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-laminate-top-fixed-height-x-ray-table-p-n-800051332/">Fuji Laminate Top Fixed Height X-ray Table (P/N: 800051332)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87099</post-id>	</item>
		<item>
		<title>Fuji Digital Radiography U-arm System w/ 17&#215;17 Detector and FDX Console Workstation</title>
		<link>https://auxomedical.com/products/fuji-digital-radiography-u-arm-system-w-17x17-detector-and-fdx-console-workstation/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Wed, 29 Apr 2026 17:39:20 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87090</guid>

					<description><![CDATA[<div>The Fuji Digital Radiography U-arm System with 17x17” detector and FDX Console Workstation offers a versatile, space-saving solution ideal for various clinical environments. Featuring the fully motorized Persona U, this single-detector DR system simplifies positioning with an innovative design that maintains precise alignment between the x-ray tube and detector regardless of tilt or angle, enabling efficient upright, seated, and supine exams, including knee and skull imaging. Its compact, all-in-one architecture eliminates the need for wall stands or overhead suspension, reducing installation time and costs, and fitting into small spaces with ease. The system includes a robust 17x17” detector, a multi-speed dual motorized universal arm with extensive movement capabilities, and a user-friendly 17” touchscreen generator console for fine-tuning techniques. Available with various generator sizes, collimation options, and mobile tables, it provides high throughput, superior image quality, and dose management, making it an optimal choice for imaging centers, orthopedic, urgent care, and hospital radiology departments seeking flexibility without compromise.</div>
<div></div>
<div><span style="font-size: 10pt;"><em>Table Pictured Not Included, Inquire for options</em></span></div>
<div></div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/04/Fuji-Persona-U-Product-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-digital-radiography-u-arm-system-w-17x17-detector-and-fdx-console-workstation/">Fuji Digital Radiography U-arm System w/ 17&#215;17 Detector and FDX Console Workstation</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji Digital Radiography U-arm System w/ 17&#215;17 Detector and FDX Console Workstation</h2>
<p>Table Pictured Not Included, Inquire for options</p>
<p>Persona U is a fully motorized, auto-positioning, single detector DR solution that&#8217;s easy to use and versatile. It provides freedom to perform virtually every type of radiographic exam, including upright, seated and supine, even knee and skull exams. Its innovative design simplifies positioning workflow, since its x-ray tube and detector are always aligned regardless of tilt position or detector angle. Its exceptionally high throughput, image quality, dose performance and flexibility make it a great space-saving alternative to traditional table- and overhead based systems without compromise.</p>
<p>The compact all-in-one design is scalable to fit tight spaces and budgets. Since the system is based on a single column floor mounted design and there is no separate wall stand or overhead suspension, it eliminates added costs of ceiling preparations, takes less time to install and fits much smaller spaces. The system is built to last and perform for imaging centers, orthopedic facilities, urgent care clinics and hospital radiology departments.</p>
<p>The standard system includes u-arm, generator, generator console, 17&#215;17&#8243; detector and FDX Console workstation. Component choices include various generator sizes, building power compatibility and auto or manual collimation.</p>
<p><strong>Other options include:</strong><br />
choice of fixed and motorized height mobile patient tables and choices of secondary detectors.</p>
<h3>Specs:</h3>
<p>Image Detector specs based on FDR ES 17c model<br />
(other CSI &amp; GOS models available)<br />
Image size: 17 x 17” (43 x 43cm)<br />
Outer dimensions: 18” x 18” x 0.6”<br />
Pixels: 2,836 x 2,832 pixels<br />
Pixel Pitch: 150 micron, 16 bits/pixel<br />
FDX Console technologist workstation. Preview image display<br />
time: 2-7 seconds<br />
NOTE: choices of detector and workstation sold separately.<br />
Universal Arm<br />
Dual speed motorized movements<br />
Vertical travel: 47.8&#8243;, speed 3.4“/sec.<br />
Arm Rotation: +150° (90° +/-30°)<br />
Tube Rotation: 180°<br />
Detector Tilt: +/-45°*<br />
SID: 39.4 &#8211; 70.8” (100 – 180 cm)<br />
Collimator: Manual or Automatic with laser &amp; light field,<br />
rails for accessories &amp; tape measure<br />
Generator Console &#8211; system includes 17&#8243; touchscreen<br />
console. Allows patient specific fine tuning of techniques<br />
and positioning parameters.</p>
<p><strong>Power Requirements:</strong><br />
Generator:<br />
Line Voltage: 230/240 VAC, +/-10%<br />
Power Consumption: 2.5 kVa, Std. 15 kVa (80 w standby)<br />
Detector: Single-phase 50/60 Hz: 110-240 V 10%, 2.1, 2.5 A<br />
Universal Arm: Single-phase 50/60 Hz: 230/240 V,10%</p>
<p><strong>Dimensions:</strong><br />
Universal Arm: Floor to ceiling or wall support<br />
Min Room: 106.3H x 84W x 84&#8243;L<br />
Dimensions (WxDxH): 84 x 66 x 88.2”; Wt. 714 lb<br />
Controller Box: 23 x 17 x 24”; 139 lb<br />
Generator: 23 x 17 x 27” (wt. varies by kW size)</p>
<p>Options &#8211; Pricing provided upon request<br />
Collimator: Manual or Automatic<br />
Generator: 40, 50, 65, 80 kW<br />
Tube: 300, 400, 600 kHu<br />
Mobile Tables &#8211; Fixed or Adjustable height (sold separately)<br />
Table Top Detector Holder<br />
Fixed Grid: 103 lines, Ratio 10:1, FD 59&#8243; (150 cm)Fixed Grid Option: 103 lines, Ratio 10:1, FD 39.4&#8243; (100 cm)</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/04/Fuji-Persona-U-Product-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-digital-radiography-u-arm-system-w-17x17-detector-and-fdx-console-workstation/">Fuji Digital Radiography U-arm System w/ 17&#215;17 Detector and FDX Console Workstation</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87090</post-id>	</item>
		<item>
		<title>Fuji FDR Essentia FS Digital Radiography Suite</title>
		<link>https://auxomedical.com/products/fuji-fdr-essentia-fs-digital-radiography-suite/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 27 Apr 2026 19:32:48 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87073</guid>

					<description><![CDATA[<div>The <strong>Fuji FDR Essentia FS Digital Radiography Suite</strong> offers a comprehensive, space-efficient solution for high-quality imaging in clinical settings. Featuring a user-friendly 10-inch touchscreen interface, the system provides streamlined controls for positioning, tube angulation, SID, and automated tube tracking, enhancing workflow and patient comfort. The standard configuration includes a floor-mounted tube stand with precise manual and motorized movement, a premium motorized elevating table supporting up to 550 lbs, and an adjustable wall stand with telescopic bucky trays compatible with 14x17" and 17x17" detectors. Designed for versatility, the suite can be configured with various generator options (from 40 kW to 65 kW) and accommodates flat panel detectors for cross-table exams, offering excellent price-performance value. Its advanced safety and workflow features, combined with precise positioning and fast image acquisition, make the Essentia FS an efficient, reliable choice for modern radiography departments seeking high performance within a compact footprint.</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-fdr-essentia-fs-digital-radiography-suite/">Fuji FDR Essentia FS Digital Radiography Suite</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="entityNameTitle slds-line-height--reset">Fuji FDR Essentia FS Digital Radiography Suite</h2>
<p>Essentia FS is a feature rich digital radiography room solution with a space saving design. The standard configuration includes a generator, floor mounted tube stand, chest stand and table. The system features an advanced user-friendly 10″ touchscreen for streamlined controls at the patient side.</p>
<p>Essentia FS is a feature rich digital radiography room solution with a space saving design. The standard configuration includes a generator, floor mounted tube stand, chest stand and table. The system features an advanced user-friendly 10″ touchscreen for streamlined controls at the patient side. The graphic interface displays tube angulation, SID, automated tube tracking and more. Complimented with a range of advanced safety and workflow features, Essentia FS is a high performance x-ray system with unparalleled price-performance ratio.</p>
<p>Floor Mounted Tube Stand:<br />
10” Intuitive Touchscreen<br />
Preset source to image distance (SID) with Auto Tube Tracking.<br />
Manual Movement Vertical/longitudinal traved controlled by electric magnet brake<br />
Tube rotation : ±135°<br />
Tube head telescopic extension: ±4.7 in. (±12 cm)<br />
Column rotation : ±90°<br />
Travel Range Vertical (Tube) : 58.7 in. (149 cm)<br />
Longitudinal (Column) : 100 in. (254 cm)<br />
Power Requirement 24 VDC, 3 A</p>
<p>Real time display of SID and tube angulation.<br />
Controls for exam parameters at the patient side, ease patient comfort and technologist workflow.</p>
<p>Premium Wall Stand<br />
Light, easy positioning with motorized, counter balanced controls and electromagnetic locks.<br />
Convenient hand grips optimize safe and steady patient positioning.<br />
The stand&#8217;s rotating bucky tray accommodates a 14&#215;17&#8243; detector.<br />
Bucky tray can be adapted to accommodate a 17&#215;17&#8243; detector during service installation.<br />
Manual Movement Vertical travel with electromagnetic brake<br />
Vertical travel Range Max : 74 in. (188 cm)<br />
(central beam-floor) Min : 15.7 in. (40cm)<br />
Power Requirement 24 VDC, 1 A</p>
<p>Motorized Elevating Table Specifications.<br />
• Patient Weight Capacity: 550 lbs.<br />
• Wireless foot switch controls</p>
<p>Tabletop Dimensions 90 x 32 in.<br />
Tabletop Travel Range Left &amp; Right : ±33.5 in. | Forward &amp; Back : ±7 in.<br />
Up &amp; down : ±10 in. | tabletop height : min. 21.5 in. ~ max. 31.5 in.<br />
Detector Travel Range Left &amp; Right 19.5 in.<br />
Power Requirement 120~240 VAC, 50/60Hz, 500 VA</p>
<p><strong>Configurations:</strong><br />
• System sold as a complete radiographic suite with chest stand, table, generator and tube stand configurations</p>
<p>• 14&#215;17&#8243; rotating bucky trays in both table and upright. 17&#215;17&#8243; bucky tray adapter can be installed at initial installation<br />
• Automatic motorized tube tracking to table and upright detector height<br />
• Generators with 3-point Control Console:<br />
• 40 kW single-phase, 230 VAC, 500 mA<br />
• 50 kW 3-phase, 230 VAC, 630 mA<br />
• 50 kW 3-phase, 480 VAC, 630 mA<br />
• 65 kW 3-phase, 480 VAC, 800 mA<br />
• X-ray Tubes with 200 kHu tube (w/40 or 50 kW gen) focal spot 300 kHu tube (w/ 40, 50 or 65 kW gen)<br />
• Manual collimator<br />
• Right or left opening non-tilting wall stand<br />
• Table top detector holder for cross table exams (option)<br />
• Single or multiple flat panel detector workflow (option)</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-fdr-essentia-fs-digital-radiography-suite/">Fuji FDR Essentia FS Digital Radiography Suite</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87073</post-id>	</item>
		<item>
		<title>Fuji FDR Clinica X Radiology Suites</title>
		<link>https://auxomedical.com/products/fuji-fdr-clinica-x-radiology-suites/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 27 Apr 2026 19:15:12 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87069</guid>

					<description><![CDATA[<div>The <strong>Fuji FDR Clinica X Radiology Suite</strong> offers a highly scalable and versatile digital X-ray solution tailored for hospital radiology departments and outpatient imaging facilities of all sizes. Incorporating Fujifilm’s innovative image processing and high-sensitivity image acquisition technologies, the system seamlessly integrates with lightweight, durable, and dose-efficient FDR D-EVO II, III, and FDR ES detectors, all managed via the Fujifilm FDX Console PLUS technologist workstation. Its ceiling suspended tube stand features easy articulation, rotation, and optional automated height tracking, collimation, and centering to streamline workflows and enhance exam speed. The suite also includes a motorized, 4-way elevating patient table with a weight capacity of 661 lbs, offering flexible positioning with longitudinal and lateral travel, while optional automatic tilting chest stands simplify patient positioning and improve comfort. Designed to optimize space, reduce costs, and operate efficiently within limited building power, the FDR Clinica X provides a comprehensive, adaptable imaging environment suitable for a wide range of clinical needs.</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/04/FDR-Clinica-X-Full-Brochure.pdf &#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-fdr-clinica-x-radiology-suites/">Fuji FDR Clinica X Radiology Suites</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Fuji FDR Clinica X Radiology Suites</h2>
<p>FDR Clinica X is a scalable digital x-ray suite for hospital radiology and outpatient imaging departments of all sizes–providing affordability and versatility without compromise. Step up your imaging to deliver Fujifilm’s innovative image processing and high sensitivity image acquisition technologies to your patient exams. FDR Clinica X is scalable to meet any department’s budgetary and workflow requirements. The system and its generator controls are fully integrated with Fujifilm’s FDX Console PLUS technologist workstation and lightweight, durable and dose efficient FDR D- EVO II, III and FDR ES detectors.</p>
<p><strong>Ceiling Suspended Tube Stand System Configuration</strong><br />
With easy articulation and rotating display, the tube extends as much as 63 in. from ceiling. Optional automated tube height tracking, collimation and centering with the height of the upright or table, eliminates workflow steps to speed exams. Allows the technologist to<br />
focus on the patient.</p>
<p><strong>Chest Stand with Automatic Tilting</strong><br />
Automatic and manual tilting upright bucky stands are optionally available. Simplifying positioning for technologists and improving exam comfort for seated patients or patients in wheelchairs.</p>
<p><strong>Elevating Patient Table</strong><br />
Motorized elevating, 4-way floating top table with a heavy-duty weight limit of 661 lbs. (300 kg) 86.6(W)x31.9(L)x1.8(H) inch top with flat edges, +/-20 ̋ Longitudinal &amp; +/-5 ̋ Lateral travel. ̃22-33 ̋</p>
<p><strong>FDR Clinica X Floor Stand Suit</strong><br />
Full featured solutions for tight spaces, lower room preparation costs and limited building power requirements.</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/04/FDR-Clinica-X-Full-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fuji-fdr-clinica-x-radiology-suites/">Fuji FDR Clinica X Radiology Suites</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87069</post-id>	</item>
		<item>
		<title>Fuji FDR D-EVO III G80i 17&#215;32 in Full Spine Detector Panel Only</title>
		<link>https://auxomedical.com/products/fdr-d-evo-iii-g80i-17x32-in-full-spine-detector-panel-only/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 21 Apr 2026 19:18:37 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87049</guid>

					<description><![CDATA[<div>The <strong>Fujifilm FDR D-EVO III G80i 17x32” Full Spine Detector Panel</strong> is an ultra-lightweight, wireless long-length DR detector designed for versatile imaging in spine, trauma, and surgical applications. Weighing just 12 lbs, it offers a seamless 17x32-inch field of view with instant imaging that eliminates stitching errors and motion retakes, providing high-quality, full-length views in a single, quick exposure. Its wireless connectivity facilitates safer, cord-free workflows in tight sterile environments such as operating rooms and ERs, while the sealed, antibacterial Hydro AG coating enhances infection control. Perfect for pre-, intra-, and post-operative imaging, this detector supports room-to-room, upright, supine, and surgical use, making it ideal for trauma, orthopedic, and surgical imaging. Its sophisticated ISS technology ensures sharp, high-resolution images with enhanced dose efficiency, and rapid preview and cycle times optimize clinical throughput. The G80i combines portability, safety, and exceptional image quality for versatile long-range radiography, all in a sleek, durable design.</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-iii-g80i-17x32-in-full-spine-detector-panel-only/">Fuji FDR D-EVO III G80i 17&#215;32 in Full Spine Detector Panel Only</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>FDR D-EVO III G80i 17&#215;32 in Full Spine Detector Panel Only</h2>
<p><strong>800052026 FDR D-EVO III G80i Panel Only</strong></p>
<p>Articulating Cart Pictured not included, see further below for additional pricing.</p>
<p>Fujifilm’s latest generation ultra-lightweight, wireless long length detector features a 17×32” field of view and weighs just 12 lbs. FDR D-EVO III G80i brings added portability for spine and leg surgery uses, along with traditional upright and supine long length exams. FDR D-EVO III G80i’s light and thin design is ideal for trauma imaging in the ER and spine, leg and other surgical procedures. It can be used pre-, intra-, and post- surgery for precise verification of planning, measurements, hardware alignments, angles, counts and more. Its wireless connectivity to the console eliminates cords for safer, easier workflow in tight, sterile OR and ER environments. Its Hydro AG protective antibacterial coating provides added safety in infection controls and sterile field uses.</p>
<h3>Features and Specs:</h3>
<ul>
<li>17×32″ instant images available anywhere you need them</li>
<li>Long length DR with enhanced portability for conventional weight bearing exams along with added flexibility for room to room, supine, surgical and trauma imaging</li>
<li>Full length views in a single, instant exposure with one seamless length detector</li>
<li>No stitching alignment or motion retakes</li>
<li>Faster acquisition of long-view images</li>
<li>Fewer exposures lower patient exposure to radiation</li>
<li>At just 12 lbs G80i is the world’s lightest long length DR detector. Ultra-light positioning and cord-free design makes it easy to move from room to room.</li>
<li>Smooth, sealed design protects circuitry from body fluids and disinfection wipe downs.</li>
<li>Fujifilm’s proprietary Hydro Ag antibacterial coating effectively prevents 99.99%** bacterial growth on the detector’s surfaces, enhancing infection controls and helping prevent HAIs</li>
<li>Choice of stands provide optimal positioning for weight bearing upright, supine, cross table, table-top and even under the surgery table</li>
<li><strong>Model name:</strong><br />
Flat Panel Detector (DR-ID 1836SE)<br />
for FDR D-EVO III System (DR-ID 1800)</li>
<li><strong>Type:</strong><br />
Cassette type detector with ISS<br />
(Irradiation Side Sampling)<br />
and glass-based TFT detector</li>
<li><strong>Scintillator:</strong><br />
GOS (Gadolinium oxysulfide)</li>
<li><strong>Detector external size:</strong><br />
850 × 460 × 15mm (Approx.)<br />
[33.4&#8243; × 18.1&#8243; × 0.6&#8243;]</li>
<li><strong>Weight:</strong><br />
Approx. 5.2kg (excludes battery pack)</li>
<li><strong>Pixel pitch/Pixels:</strong><br />
Pixel size 150µm/5,376 × 2,832pixels</li>
<li><strong>Detector Area:</strong><br />
31.8” x 16.7” (Pixel matrix size 5376 x 2832 pixels)</li>
<li><strong>Field of View:</strong><br />
16.7&#8243;×31.8&#8243;</li>
<li><strong>Wireless standard:</strong><br />
IEEE 802.11n, IEEE 802.11ac<br />
(2.4GHz, W52/W53/W56/W58)</li>
<li><strong>Image preview:</strong><br />
Less than 2.5sec (wired/wireless)</li>
<li><strong>Cycle time:</strong><br />
Less than 7.5sec (wired/wireless)<br />
Less than 10sec (SmartSwitch)</li>
<li><strong>Battery recharging time:</strong><br />
Approx. 3hours (with battery charger)</li>
</ul>
<p>&nbsp;</p>
<p><strong>Options/Add Ons:</strong></p>
<ul>
<li>Add FDX Console</li>
<li>Add FDR Flex w/ Laptop</li>
<li>800052053 FDR D-EVO III G80i Articulating Cart</li>
<li>800052260 Mobile Detector Holder for G80i</li>
<li>800052051 FDR D-EVO III G80i Weight Bearing Cap</li>
<li>800052052 FDR D-EVO III G80i Grid</li>
</ul>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-iii-g80i-17x32-in-full-spine-detector-panel-only/">Fuji FDR D-EVO III G80i 17&#215;32 in Full Spine Detector Panel Only</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87049</post-id>	</item>
		<item>
		<title>Fuji FDR D-EVO GL 17&#215;49 in Full Spine Length Detector With Rolling Stand</title>
		<link>https://auxomedical.com/products/fdr-d-evo-gl-17x49-in-full-spine-length-detector-with-rolling-stand/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 21 Apr 2026 19:08:11 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87047</guid>

					<description><![CDATA[<div>The <strong>Fujifilm FDR D-EVO GL 17x49” Full Spine Length Detector</strong> with rolling stand is engineered to provide seamless, high-quality long-view radiography in a single exposure, significantly enhancing workflow efficiency and patient comfort. Its expansive 17x49-inch imaging area extends the traditional long-length field of view by three inches, accommodating a wider range of patient sizes and reducing retakes caused by anatomy cutoff. Incorporating Fujifilm’s advanced Dynamic Visualization processing, the detector delivers exceptional detail with optimized contrast and window/level capabilities. The patented ISS (Irradiated Side Sampling) technology positions the capture electronics on the irradiation side, dramatically reducing scatter and attenuation, which results in sharper images at lower doses—up to 50% less when used with Virtual Grid software. Enhanced noise reduction circuitry improves sensitivity, especially in dense areas like the mediastinum, providing a 1.7 times higher Detective Quantum Efficiency (DQE). The SmartSwitch feature enables automatic detection for quick, seamless imaging, while the lightweight design (about 43 lbs) and fast readout times (as low as 6 seconds for a 17x17 segment) make it ideal for long-view radiography, outpatient clinics, and mobile imaging environments.</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/04/FDR-D-EVO-GL-Product-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-gl-17x49-in-full-spine-length-detector-with-rolling-stand/">Fuji FDR D-EVO GL 17&#215;49 in Full Spine Length Detector With Rolling Stand</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>FDR D-EVO GL 17&#215;49 in Full Spine Length Detector With Rolling Stand</h2>
<p><strong>800046893 FDR D-EVO GL with Rolling Stand</strong></p>
<p>Fuji FDR D-EVO GL long-view single exposure detector ensures consistent, easy patient positioning and repeatable image acquisition, reducing exam discomfort for a better patient experience. FDR D-EVO GL’s single exposure DR, when used with Virtual Grid software, can reduce dose as much as 50% compared to grid exams.</p>
<p>The Fuji FDR D-EVO-GL is 17×49 inches, expanding the traditional 14 inch CR long length field of view by 3 full inches to better accommodate a variety of patient sizes and help prevent retakes due to anatomy cut off.</p>
<p>The Fuji FDR D-EVO-GL enhances the workflow of long-view radiography by capturing the entire image in a single exposure in just a few seconds, reducing the chance for patient motion-induced artifacts and time for the patient to remain still.</p>
<h3>Features:</h3>
<p><strong>Refined Dynamic Visualization image processing produces exceptional images</strong><br />
FDR D-EVO GL utilizes the latest Fujifilm digital image processing technology, including Dynamic Visualization, which optimizes image display based on recognition of contrast levels throughout the entire exposure field. The resulting first-up images have outstanding detail and greater window and leveling capability in PACS.</p>
<p><strong>Intelligent Virtual Grid image processing for situations where grid use can be challenging</strong><br />
Virtual Grid intelligent image processing replaces the use of a grid to enhance contrast and improve clarity while reducing dose as much as 50% compared to exams performed with a grid.</p>
<p><strong>Patented ISS capture technology promotes high sensitivity</strong><br />
Fujifilm’s proprietary Irradiated Side Sampling (ISS) positions its capture electronics (TFTs) at the irradiation side, in contrast to traditional detectors. This design significantly suppresses scattering and attenuation of X-ray signals, improving efficiency to produce sharper images at lower doses compared to traditional designs.</p>
<p><strong>Noise reduction circuitry improves sensitivity in high absorption regions</strong><br />
A unique, Fujifilm innovation in noise reduction circuitry maximizes signal strength to improve image quality in high absorption areas. This enhancement achieves 1.7 times the DQE of previous models, with as little as 0.03mrad dose. Visibility of dense areas such as the heart and mediastinum is greatly improved.</p>
<p><strong>SmartSwitch Technology</strong><br />
Fujifilm’s SmartSwitch technology enables automatic x-ray detection. FDR D-EVO GL automatically senses exposures to trigger image capture, allowing easier, faster interfacing with any x-ray system</p>
<h3>Specs:</h3>
<ul>
<li>Detector external size: 52.7 x 22.3 x 2.0 in.</li>
<li>Weight: Approx. 43.0 lbs.</li>
<li>Pixel pitch Pixels: 150 μm</li>
<li>Image preview: 8228 x 2832 pixels: 17 x 49 in. size reading: 9-20 sec., 17 x 17 in. size reading (single detector segment): 6 sec.</li>
<li>Cycle time: 17 x 49 in. size reading: 26 sec., 17 x 17 in. size reading (single detector segment): 10 sec.</li>
</ul>
<p><strong>Options/Add Ons:</strong></p>
<ul>
<li>800047463 FDR D-EVO GL Weight Bearing Cap</li>
<li>800053594 FDR D-EVO GL Grid 8-1 103 Rev. A (for fixed and articulating stands)</li>
<li>800053698 FDR D-EVO GL Grid for Mobile Stand 8-1 103 LPI A</li>
<li>800048016 Rolling Workstation Cart</li>
<li>800048577 MP Holder for FDR D-EVO GL Articulating Stand</li>
<li>16515734 FDR D-EVO GL SE Cable 20M</li>
<li>16515722 FDR D-EVO GL SE Cable 10M</li>
<li>16663103 FDR D-EVO GL SE Cable 4M</li>
<li>800048580 25’ 125V Hospital Grade Power Cord</li>
<li>800046494 FDR D-EVO GL Rolling Stand</li>
</ul>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/04/FDR-D-EVO-GL-Product-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-gl-17x49-in-full-spine-length-detector-with-rolling-stand/">Fuji FDR D-EVO GL 17&#215;49 in Full Spine Length Detector With Rolling Stand</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87047</post-id>	</item>
		<item>
		<title>FDR D-EVO III G43 17 x 17” Detector Panel Only</title>
		<link>https://auxomedical.com/products/fdr-d-evo-iii-g43-17-x-17-detector-panel-only/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 21 Apr 2026 18:49:59 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=87046</guid>

					<description><![CDATA[<div>The <strong>Fujifilm FDR D-EVO III G43 17 x 17” Detector Panel</strong> is the industry’s lightest DR detector, utilizing innovative film-based TFT circuitry that makes it 40% lighter than the first-generation model, enhancing portability and handling. Featuring a patented Irradiated Side Sampling (ISS) technology, it bonds capture electronics on the x-ray side, reducing scattering and attenuation for sharper images at lower doses—achieving a 33% higher Detective Quantum Efficiency (DQE). Its durable, flexible design withstands tough medical environments, with quick battery replacement for rapid readiness—a full backup in approximately 90 seconds—and expanded spectrum support for outdoor use. Advanced image processing, including Virtual Grid for gridless imaging and Dynamic Visualization II for optimized contrast based on anatomy, further enhances image quality while enabling up to 50% dose reduction. Weighing only 4.6 lbs, with fast image preview (less than 2 seconds) and cycle times under 10 seconds, this detector is ideal for room retrofit, mobile, emergency, and disaster response applications, offering unmatched flexibility, durability, and superior imaging performance.</div>
<div>[vc_btn title="Download Brochure" style="flat" shape="square" link="url:/wp-content/uploads/2026/04/FDR-D-EVO-III-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-iii-g43-17-x-17-detector-panel-only/">FDR D-EVO III G43 17 x 17” Detector Panel Only</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>FDR D-EVO III G43 17 x 17” Detector Panel Only</h2>
<h3>Features:</h3>
<p><strong>Fujifilm’s lightest DR detector with flexible film-based TFT circuitry</strong><br />
By replacing the glass-based TFT layer with a high-tech thin film layer, FDR D-EVO III is 40% lighter than the original 1st generation FDR D-EVO model and 20% lighter than FDR D-EVO II.</p>
<p><strong>Higher DQE 33% (1Lp/mm-RQA5 1mR)</strong><br />
Innovative film-based capture layer helps reduce signal blur, providing excellent DQE and dose performance.</p>
<p><strong>Enhanced durability to endure tough medical environments</strong><br />
By eliminating the most fragile (glass) component, the new flexible film-based TFT detector improves durability and decreases risks of shock damage compared to previous FDR D-EVO models.</p>
<p><strong>Patented ISS capture technology promotes high sensitivity</strong><br />
Equipped with Fujifilm’s patented Irradiated Side Sampling (ISS) technology which bonds its capture electronics (TFTs) to the x-ray irradiation side, in contrast to traditional detectors. This design suppresses scattering and attenuation of x-ray signals, to produce sharper images at lower doses compared to traditional designs.</p>
<p><strong>Unique formulation of large and small phosphor particles at a optimal ratios, enhances x-ray absorption</strong><br />
Increased x-ray absorption is achieved through our uniquely formulated scintillator layer, which employs photographic film technology to optimize the blending ratio of phosphor particles to minimize blur and enhance sharpness.</p>
<p><strong>Fujifilm’s noise reduction circuitry improves detector sensitivity in high absorption and low dose images</strong><br />
Uniquely engineered noise reduction circuitry reduces noise in the image to improve signal strength. This results in 33% DQE even at 0.1mR. The granularity and visibility of dense, low penetration or ultra low dose regions are improved.</p>
<p><strong>Improved handling</strong><br />
Simple battery replacement workflow<br />
The battery can easily be replaced with one hand and the detector can be back up and ready in ~90 seconds. This eliminates concerns about battery life or on-demand battery swaps even in the midst of critical care.</p>
<p><strong>Suitable for outdoor use with an expanded spectrum</strong><br />
Supports 2.4GHz and 5GHz (W52/53/56/58)* spectrum. Suitable for outdoor use during disaster response.</p>
<p><strong>Memory Mode</strong><br />
Dedicated memory mode enables added emergency uses. Built-in memory stores up to 100 images. Images are retained even if detector power is interrupted. Digital readout on detector face tracks images stored and increments as they are acquired.</p>
<p><strong>Flexibility – On-Demand Use</strong><br />
FDR D-EVO III’s unique combination of form and function brings significant value to traditional room retrofit and mobile uses. The additional capabilities of Memory Mode and Smart Switch bring added value for emergency, on-demand backup and failsafe uses with any portable, room or even for remote off-site and disaster response uses.</p>
<p><strong>Advanced image processing</strong><br />
Virtual Grid: High quality images without a physical grid<br />
Advanced processing simulates scatter clean up without a physical grid, correcting for the effects of scatter radiation while retaining contrast and sharpness. Eliminating the grid improves patient comfort, simplifies positioning and allows as much as 50% lower dose compared to grid exams. Grid cutoff and retakes associated with misalignment of X-ray tube and grid are also prevented.</p>
<p><strong>Dynamic Visualization II: Intelligent feature recognition technology optimizes image quality</strong><br />
Advanced algorithms optimize contrast and density based on anatomic definition, hardware and thickness characteristics, resulting in outstanding detail and greater window and leveling capability in PACS.</p>
<h3>Specs:</h3>
<ul>
<li>Type: Detector with patented ISS (Irradiation Side Sampling) and flexible film-based TFT detector technology</li>
<li>Scintillator: GOS (Gadolinium oxysulfide)</li>
<li>Detector external size: 18 x 18 x 0.6″ approx. (460 x 460 x 15mm)</li>
<li>Weight: 4.6 lbs. (2.1 kg) excludes battery</li>
<li>Pixel pitch: 150μm, 16 bits per pixel</li>
<li>Pixels: 2836 x 2336 pixels</li>
<li>Image preview: Less than 2 sec</li>
<li>Cycle time: Less than 10 sec (wired), Less than 11 sec (SmartSwitch)</li>
<li>Battery recharging time: Approx. 3 hours (with battery charger), Approx. 4 hours (with Docking Stand)</li>
</ul>
<p><strong>ADDITIONAL Configurations:</strong><br />
ADD FDX<br />
ADD Docking Stand<br />
ADD Power Box</p>
<p><strong>FDR D-EVO III Accessories</strong><br />
16648725 FDR D-EVO III Battery (standard)<br />
16648737 FDR D-EVO III Battery Charger Upgrade Kit<br />
800049194 FDR D-EVO III Battery Charger Kit<br />
800051782 FDR D-EVO III 25&#215;30 weight bearing cap</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/04/FDR-D-EVO-III-Brochure.pdf" title="" target="_blank">Download Brochure</a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/fdr-d-evo-iii-g43-17-x-17-detector-panel-only/">FDR D-EVO III G43 17 x 17” Detector Panel Only</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">87046</post-id>	</item>
	</channel>
</rss>
