<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Alaris 8100 &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/tag/alaris-8100/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Thu, 29 Jan 2026 21:51:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>Alaris 8100 &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>Overview of the Alaris 8100 Infusion Pump and Point‑of‑Care System</title>
		<link>https://auxomedical.com/2026/01/overview-of-the-alaris-8100-infusion-pump-and-point-of-care-system/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Thu, 29 Jan 2026 21:50:29 +0000</pubDate>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[Product Specific Catalogs]]></category>
		<category><![CDATA[Resources]]></category>
		<category><![CDATA[Alaris 8015]]></category>
		<category><![CDATA[Alaris 8100]]></category>
		<category><![CDATA[Alaris Medley]]></category>
		<category><![CDATA[Alaris Medley Pumps]]></category>
		<category><![CDATA[Auxo Medical]]></category>
		<category><![CDATA[CareFusion]]></category>
		<category><![CDATA[Infusion Pump]]></category>
		<guid isPermaLink="false">https://auxomedical.com/?p=86423</guid>

					<description><![CDATA[<p>The Alaris 8100 is a large‑volume infusion pump module designed to work as part of the modular BD Alaris System (formerly CareFusion). In hospitals, you usually see it attached to a central Point‑of‑Care Unit (PCU), which provides the display, user interface, and safety software (Guardrails dose error reduction system). Used together, the 8100 and PCU [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/2026/01/overview-of-the-alaris-8100-infusion-pump-and-point-of-care-system/">Overview of the Alaris 8100 Infusion Pump and Point‑of‑Care System</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Alaris 8100 is a large‑volume infusion pump module designed to work as part of the modular BD Alaris System (formerly CareFusion). In hospitals, you usually see it attached to a central Point‑of‑Care Unit (PCU), which provides the display, user interface, and safety software (Guardrails dose error reduction system).</p>
<p>Used together, the 8100 and PCU form a “smart pump” platform that standardizes IV medication delivery across multiple clinical areas: medical‑surgical floors, ICUs, EDs, ORs, and pediatric units.</p>
<blockquote><p>Note: Details below are general and not a substitute for the official operator’s manual or institutional training. Always refer to manufacturer documentation and hospital policy for exact specifications and instructions.</p></blockquote>
<hr />
<h2>System Architecture: How the Alaris Modules Work Together</h2>
<p>The BD Alaris System is modular:</p>
<ul>
<li><a href="https://auxomedical.com/products/alaris-medley-8015/"><strong>Alaris PCU (Point‑of‑Care Unit, e.g., model 8015)</strong></a><br />
The central controller with screen, keypad, battery, and networking. It powers and coordinates all attached modules.</li>
<li><a href="https://auxomedical.com/products/alaris-medley-8100/"><strong>Alaris 8100 Pump Module</strong></a><br />
A large‑volume infusion module for delivering fluids, medications, blood and blood products.</li>
</ul>
<p>Multiple modules can be attached to one PCU to build a patient‑specific configuration—e.g., several 8100 pumps plus a syringe module or monitoring module.</p>
<hr />
<h2>Alaris 8100 Infusion Pump Module</h2>
<h3>Intended Use</h3>
<p>The Alaris 8100 is a <strong>large‑volume, channel‑based infusion pump</strong> intended for controlled IV administration of:</p>
<ul>
<li>Crystalloids (e.g., saline, dextrose solutions)</li>
<li>Colloids</li>
<li>Medications (continuous or intermittent)</li>
<li>Blood and blood products</li>
<li>Parenteral nutrition and lipids (per institutional policy)</li>
</ul>
<p>It is designed for <strong>adult, pediatric, and neonatal</strong> patients when programmed and used by trained healthcare professionals within defined drug libraries and protocols.</p>
<hr />
<h3>Key Features of the 8100 Pump Module</h3>
<p><strong>1. Large‑volume, peristaltic infusion technology</strong></p>
<ul>
<li>Volumetric pump using a dedicated pumping segment in the IV set</li>
<li>Designed for accurate delivery of large‑volume infusions</li>
<li>Compatible with specific BD/Alaris infusion sets incorporating anti–free‑flow protection</li>
</ul>
<p><strong>2. Smart pump safety with Guardrails</strong></p>
<ul>
<li>Relies on the PCU’s <strong>Guardrails Dose Error Reduction System (DERS)</strong></li>
<li>Supports:
<ul>
<li>Weight‑based dosing (e.g., mcg/kg/min)</li>
<li>Standard mL/hr programming</li>
<li>Volume‑to‑be‑infused (VTBI) over time</li>
</ul>
</li>
<li>Applies drug‑specific <strong>soft and hard limits</strong> and alerts based on a hospital‑defined drug library</li>
</ul>
<p><strong>3. Primary and secondary (piggyback) infusions</strong></p>
<ul>
<li>Allows a <strong>primary</strong> infusion (e.g., maintenance fluids) with a <strong>secondary</strong> infusion (e.g., antibiotic piggyback) through the same line</li>
<li>Automates switching between secondary and primary according to programmed parameters</li>
</ul>
<p><strong>4. Flexible clinical profiles</strong></p>
<ul>
<li>Multiple configurable “profiles” or care areas (e.g., Med‑Surg, ICU, NICU, Oncology, OR), each with:
<ul>
<li>Its own drug library</li>
<li>Tailored limits and clinical advisories</li>
</ul>
</li>
</ul>
<p><strong>5. Channel‑based design</strong></p>
<ul>
<li>Each 8100 is a <strong>single channel</strong>; multiple channels/modules can be stacked on one PCU</li>
<li>Facilitates independent control of multiple concurrent infusions for one patient</li>
</ul>
<p><strong>6. Safety and alarm features</strong></p>
<p>Typical safety functions include:</p>
<ul>
<li>Upstream and downstream <strong>occlusion detection</strong></li>
<li><strong>Air‑in‑line</strong> detection and alarm</li>
<li>Detection of <strong>free‑flow risks</strong> via dedicated anti–free‑flow mechanisms in the sets</li>
<li><strong>Door open</strong> / misload detection</li>
<li>Audible and visual alarms with clear status indication at the channel and on the PCU</li>
</ul>
<p><strong>7. Integrated event logging</strong></p>
<ul>
<li>Logs alarms, changes in settings, start/stop events, and overrides of Guardrails limits</li>
<li>Supports quality improvement, incident review, and compliance monitoring</li>
</ul>
<hr />
<h3>Typical Technical Characteristics (High‑Level)</h3>
<p>While exact numbers vary by configuration and region, these are the <strong>typical specification categories</strong> for the 8100 module:</p>
<ul>
<li><strong>Pump type:</strong> Large‑volume peristaltic pump</li>
<li><strong>Infusion modes:</strong>
<ul>
<li>Rate (mL/hr)</li>
<li>VTBI over time</li>
<li>Weight‑based dosing (e.g., mcg/kg/min, units/kg/hr) when used with Guardrails</li>
</ul>
</li>
<li><strong>Therapies:</strong> Continuous, intermittent, primary/secondary, keep‑vein‑open (KVO)</li>
<li><strong>Accuracy:</strong> Designed to meet or exceed international infusion device standards (e.g., IEC 60601‑2‑24) for large‑volume pumps</li>
<li><strong>Power:</strong> Receives power and control from the PCU; no separate battery in the module</li>
<li><strong>User interface:</strong> Programming and monitoring via the PCU’s display; the module provides status lights and labels</li>
</ul>
<p>For exact flow ranges, accuracy percentages, dimensions, and weight, you should reference the official BD Alaris 8100 technical datasheet or operator’s manual, as these are treated as regulated specifications.</p>
<hr />
<h2>Alaris PCU – Point‑of‑Care System</h2>
<p>The <strong>Alaris PCU</strong> is the central “brain” and interface of the system. It ties together the 8100 pump modules and other modules into a single, coordinated platform at the bedside.</p>
<h3>Core Functions</h3>
<p><strong>1. Central user interface</strong></p>
<ul>
<li>Color or monochrome screen (depending on generation) with soft keys and keypad</li>
<li>Provides:
<ul>
<li>Drug selection, rate/dose programming</li>
<li>Alarm details and troubleshooting prompts</li>
<li>Overview of all active channels on that PCU</li>
</ul>
</li>
<li>Supports <strong>care area (profile) selection</strong> on startup so that the right drug library and limits are loaded (e.g., ICU vs Med‑Surg)</li>
</ul>
<p><strong>2. Guardrails Dose Error Reduction System (DERS)</strong></p>
<p>Guardrails is the primary safety software layer:</p>
<ul>
<li><strong>Hospital‑defined drug library</strong>:
<ul>
<li>Standard concentrations and dosing units</li>
<li>Minimum and maximum rates/doses for each therapy</li>
<li>Weight ranges, infusion duration constraints</li>
<li>Clinical advisories or warnings</li>
</ul>
</li>
<li><strong>Soft limits:</strong> Can be overridden with clinical justification, but the event is logged</li>
<li><strong>Hard limits:</strong> Cannot be overridden; require reprogramming within safe bounds</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Reduces programming and decimal errors</li>
<li>Helps standardize practice across units and shifts</li>
<li>Provides data for continuous quality improvement (e.g., alerts on how often limits are approached or overridden)</li>
</ul>
<p><strong>3. Modular configuration and expandability</strong></p>
<ul>
<li>Multiple infusion and monitoring modules can be attached to a single PCU for one patient</li>
<li>Common examples:
<ul>
<li>2–4 Alaris 8100 pump channels for fluids, vasoactive drips, maintenance meds</li>
<li>1 syringe module for very low‑rate, high‑concentration drugs</li>
<li>1 PCA module for post‑operative analgesia</li>
</ul>
</li>
<li>All modules share a common alarm system and user interface through the PCU</li>
</ul>
<p><strong>4. Power and battery backup</strong></p>
<ul>
<li>Internal battery in the PCU supports continued operation of all attached modules for a limited time during transport or power outages (hours, depending on configuration and load)</li>
<li>Line‑powered through standard AC mains when docked or plugged in</li>
</ul>
<p><strong>5. Connectivity and integration (where implemented)</strong></p>
<p>Depending on configuration and hospital IT infrastructure, the PCU may support:</p>
<ul>
<li><strong>Network connectivity</strong> (wired and/or wireless) for:
<ul>
<li>Drug library distribution and updates</li>
<li>Centralized logs and analytics</li>
<li>Firmware updates</li>
</ul>
</li>
<li><strong>EMR/EHR integration</strong> (smart pump interoperability), which can include:
<ul>
<li>Auto‑documentation of infusion data into the electronic record</li>
<li>Auto‑programming from the EHR (orders → pump), reducing manual keying</li>
<li>Closed‑loop medication safety when combined with barcoding and CPOE</li>
</ul>
</li>
</ul>
<p>Actual connectivity options vary by software version, regulatory status in each country, and specific hospital implementation.</p>
<hr />
<h2>Typical Clinical Use Cases</h2>
<p>The Alaris 8100 with PCU is designed for professional use in a range of settings.</p>
<h3>1. General Medical‑Surgical Units</h3>
<p>Common uses:</p>
<ul>
<li>Maintenance IV fluids (e.g., saline, dextrose)</li>
<li>Intermittent IV antibiotics via secondary (piggyback) infusions</li>
<li>Electrolyte replacement (e.g., potassium, magnesium) within Guardrails limits</li>
<li>Hydration for patients unable to take adequate oral fluids</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Standardized medication delivery and workflows</li>
<li>Reduction in programming errors through Guardrails libraries</li>
<li>A scalable system—additional channels/modules can be added if a patient’s needs escalate</li>
</ul>
<hr />
<h3>2. Intensive Care Units (ICU, CCU, NICU, PICU)</h3>
<p>In critical care, the 8100 is often used alongside other modules:</p>
<ul>
<li>Continuous vasoactive drugs (e.g., inotropes, vasopressors)</li>
<li>Sedation infusions and analgesia (where large‑volume devices are appropriate)</li>
<li>Parenteral nutrition (TPN) and lipids</li>
<li>High‑risk titratable medications requiring very precise rates</li>
<li>Neonatal and pediatric fluid and medication infusions (with dedicated pediatric profiles and weight‑based dosing)</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Multiple 8100 channels allow simultaneous, independently controlled infusions</li>
<li>Guardrails limits can be tightened for high‑risk drugs</li>
<li>Centralized view of all active therapies on the PCU facilitates complex ICU workflows</li>
</ul>
<hr />
<h3>3. Emergency Department and Perioperative Settings</h3>
<p>Use cases:</p>
<ul>
<li>Rapid initiation of fluid resuscitation after stabilization</li>
<li>Controlled medication infusions (e.g., antiarrhythmics, antihypertensives)</li>
<li>Perioperative antibiotics and maintenance fluids in pre‑/post‑op areas</li>
<li>Transition of infusions from ED to ICU/ward without changing hardware</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Consistent platform across departments, simplifying handoffs</li>
<li>Guardrails reduces reliance on mental math during high‑stress situations</li>
<li>Battery backup and modularity support safe patient transport within the hospital</li>
</ul>
<hr />
<h3>4. Oncology and Specialized Infusions</h3>
<p>In oncology and other specialized areas (subject to local policy and protocols):</p>
<ul>
<li>Standardized delivery of certain <strong>chemotherapy</strong> agents</li>
<li>Complex protocols with staged infusions (pre‑hydration, drug, post‑hydration)</li>
<li>Supportive therapies: antiemetics, analgesics, biologics, immunotherapies</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Drug‑specific limits and advisories in Guardrails for high‑risk agents</li>
<li>Detailed logging for documentation and auditing of high‑alert medications</li>
</ul>
<blockquote><p>Many institutions use specialized protocols and additional verification steps (e.g., pharmacy double‑checks, barcode administration) for chemotherapy and other high‑risk infusions beyond what the pump alone provides.</p></blockquote>
<hr />
<h3>5. Pediatrics and Neonatology</h3>
<p>With appropriately configured pediatric/neonatal profiles:</p>
<ul>
<li>Weight‑based dosing with strict limits and customized drug lists</li>
<li>Low‑volume maintenance fluids and continuous medication infusions</li>
<li>Carefully controlled electrolyte and nutrition solutions</li>
</ul>
<p>Benefits:</p>
<ul>
<li>Reduced risk of decimal or miscalculation errors</li>
<li>Library‑based dosing ranges tailored to very small patients</li>
<li>Ability to standardize around weight‑based protocols</li>
</ul>
<p>In very low‑flow, high‑concentration pediatric therapies, syringe pumps (e.g., Alaris 8110) are often used alongside 8100 modules.</p>
<hr />
<h2>Implementation and Safety Considerations</h2>
<p>When hospitals deploy the Alaris 8100 and PCU system, typical focus areas include:</p>
<ul>
<li><strong>Drug library design and maintenance</strong>
<ul>
<li>Multidisciplinary team (pharmacy, nursing, physicians, biomedical engineering, informatics)</li>
<li>Regular review of limits based on incident data and evolving evidence</li>
<li>Ongoing updates pushed to all devices</li>
</ul>
</li>
<li><strong>Training and competency</strong>
<ul>
<li>Initial and periodic staff training on:
<ul>
<li>Selecting the correct profile</li>
<li>Using Guardrails effectively</li>
<li>Responding to alarms</li>
</ul>
</li>
<li>Orientation for new staff and travelers</li>
</ul>
</li>
<li><strong>Governance and analytics</strong>
<ul>
<li>Reviewing Guardrails logs to see:
<ul>
<li>Which limits are frequently approached or overridden</li>
<li>Where protocols or education need adjustment</li>
</ul>
</li>
<li>Monitoring alarm burden and optimizing settings</li>
</ul>
</li>
<li><strong>Maintenance and regulatory compliance</strong>
<ul>
<li>Scheduled preventive maintenance and performance verification by biomedical engineering</li>
<li>Implementation of manufacturer and regulatory safety notices, recalls, and software updates</li>
</ul>
</li>
</ul>
<hr />
<h2>Buy your Alaris 8100 Infusion Pump and Alaris Point of Care System From Auxo Medical</h2>
<p>The <strong>Alaris 8100 Infusion Pump Module</strong>, integrated with the <strong>Alaris PCU Point‑of‑Care System</strong>, provides a flexible, modular “smart pump” platform for controlled IV therapy across a wide range of clinical settings.</p>
<p>Key strengths of the system include:</p>
<ul>
<li>Modular architecture to tailor the setup to each patient</li>
<li>Guardrails DERS for standardized, safer dosing</li>
<li>Support for diverse infusion types—primary, secondary, weight‑based, and VTBI</li>
<li>Integration capabilities with hospital networks and EHRs (where implemented)</li>
</ul>
<div class="woocommerce columns-4 "><ul class="products row"><li class="col-xs-12 col-sm-6 col-md-3 col-lg-3 post-3632 product type-product status-publish has-post-thumbnail product_brand-alaris product_cat-infusion-and-syringe-pumps product_tag-alaris product_tag-infusion-pump product_tag-point-of-care-module product_tag-refurbished pa_condition-refurbished first instock taxable shipping-taxable purchasable product-type-simple">
  <div class="productbox">
	<a href="https://auxomedical.com/products/alaris-8000-point-of-care/" class="woocommerce-LoopProduct-link woocommerce-loop-product__link">
	<div class="productimagebox">
			<img fetchpriority="high" decoding="async" width="520" height="622" src="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-520x622.jpg" class="attachment-woocommerce_thumbnail size-woocommerce_thumbnail" alt="Alaris Medley 8000 Point of Care Unit" srcset="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-520x622.jpg 520w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-251x300.jpg 251w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-342x409.jpg 342w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015.jpg 705w" sizes="(max-width: 520px) 100vw, 520px" data-attachment-id="80237" data-permalink="https://auxomedical.com/?attachment_id=80237" data-orig-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015.jpg" data-orig-size="705,843" data-comments-opened="0" data-image-meta="{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}" data-image-title="Alaris Medley 8000 Point of Care Unit" data-image-description="&lt;p&gt;Alaris Medley 8000 Point of Care Unit&lt;/p&gt;
" data-image-caption="" data-large-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015.jpg" /><a href="https://auxomedical.com/products/alaris-8000-point-of-care/?add-to-cart=3632" aria-describedby="woocommerce_loop_add_to_cart_link_describedby_3632" data-quantity="1" class="button product_type_simple add_to_cart_button ajax_add_to_cart" data-product_id="3632" data-product_sku="AM-Alaris-8000" aria-label="Add to cart: &ldquo;Alaris 8000 PC Point-of-Care Unit&rdquo;" rel="nofollow" data-success_message="&ldquo;Alaris 8000 PC Point-of-Care Unit&rdquo; has been added to your cart" role="button">Add to cart</a>	<span id="woocommerce_loop_add_to_cart_link_describedby_3632" class="screen-reader-text">
			</span>
		
    </div><!-- .productimagebox -->
      
	<div class="productcontent">
		<h3><a href="https://auxomedical.com/products/alaris-8000-point-of-care/">Alaris 8000 PC Point-of-Care Unit</a></h3>

		
	<span class="price"><span class="woocommerce-Price-amount amount"><bdi><span class="woocommerce-Price-currencySymbol">&#36;</span>660.00</bdi></span></span>
The Alaris 8000 PC Point-of-Care Unit serves as the central hub of the Alaris System, offering a unified user interface that simplifies programming and monitoring of infusion modules, thereby reducing complexity at the point of care. Formerly known as the&hellip;	</div><!-- .productcontent -->

	

	</a>    
    
  </div><!-- .productbox -->
</li>
<li class="col-xs-12 col-sm-6 col-md-3 col-lg-3 post-2203 product type-product status-publish has-post-thumbnail product_brand-alaris product_cat-infusion-and-syringe-pumps product_tag-alaris product_tag-infusion-pump product_tag-medley-8100 product_tag-refurbished pa_condition-refurbished  instock taxable shipping-taxable purchasable product-type-simple">
  <div class="productbox">
	<a href="https://auxomedical.com/products/alaris-medley-8100/" class="woocommerce-LoopProduct-link woocommerce-loop-product__link">
	<div class="productimagebox">
			<img decoding="async" width="520" height="1037" src="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-520x1037.jpg" class="attachment-woocommerce_thumbnail size-woocommerce_thumbnail" alt="Alaris Medley 8100 Infusion Pump" srcset="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-520x1037.jpg 520w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-800x1596.jpg 800w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-501x1000.jpg 501w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-150x300.jpg 150w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-768x1532.jpg 768w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-513x1024.jpg 513w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-770x1536.jpg 770w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-1027x2048.jpg 1027w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-205x409.jpg 205w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump.jpg 1106w" sizes="(max-width: 520px) 100vw, 520px" data-attachment-id="81762" data-permalink="https://auxomedical.com/?attachment_id=81762" data-orig-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump.jpg" data-orig-size="1106,2206" data-comments-opened="0" data-image-meta="{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}" data-image-title="Alaris Medley 8100 Infusion Pump" data-image-description="&lt;p&gt;Alaris Medley 8100 Infusion Pump&lt;/p&gt;
" data-image-caption="" data-large-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8100-Infusion-Pump-513x1024.jpg" /><a href="https://auxomedical.com/products/alaris-medley-8100/?add-to-cart=2203" aria-describedby="woocommerce_loop_add_to_cart_link_describedby_2203" data-quantity="1" class="button product_type_simple add_to_cart_button ajax_add_to_cart" data-product_id="2203" data-product_sku="AM-Alaris-8100" aria-label="Add to cart: &ldquo;Alaris Medley 8100 Infusion Pump&rdquo;" rel="nofollow" data-success_message="&ldquo;Alaris Medley 8100 Infusion Pump&rdquo; has been added to your cart" role="button">Add to cart</a>	<span id="woocommerce_loop_add_to_cart_link_describedby_2203" class="screen-reader-text">
			</span>
		
    </div><!-- .productimagebox -->
      
	<div class="productcontent">
		<h3><a href="https://auxomedical.com/products/alaris-medley-8100/">Alaris Medley 8100 Infusion Pump</a></h3>

		
	<span class="price"><span class="woocommerce-Price-amount amount"><bdi><span class="woocommerce-Price-currencySymbol">&#36;</span>995.00</bdi></span></span>
The Alaris Medley 8100 Infusion Pump Module is a high-capacity, large-volume infusion device designed to seamlessly integrate into the modular Alaris System, operating in conjunction with the Alaris PC Point of Care Unit (Models 8000 or 8015). Compact and lightweight,&hellip;	</div><!-- .productcontent -->

	

	</a>    
    
  </div><!-- .productbox -->
</li>
<li class="col-xs-12 col-sm-6 col-md-3 col-lg-3 post-2200 product type-product status-publish has-post-thumbnail product_brand-alaris product_cat-infusion-and-syringe-pumps product_tag-alaris product_tag-infusion-pump product_tag-medley-8015 product_tag-point-of-care-module product_tag-refurbished pa_condition-refurbished  instock taxable shipping-taxable purchasable product-type-simple">
  <div class="productbox">
	<a href="https://auxomedical.com/products/alaris-medley-8015/" class="woocommerce-LoopProduct-link woocommerce-loop-product__link">
	<div class="productimagebox">
			<img decoding="async" width="520" height="699" src="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-520x699.jpeg" class="attachment-woocommerce_thumbnail size-woocommerce_thumbnail" alt="Alaris Medley 8015 Point of Care Module" srcset="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-520x699.jpeg 520w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-223x300.jpeg 223w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-762x1024.jpeg 762w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-768x1032.jpeg 768w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-1143x1536.jpeg 1143w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-1524x2048.jpeg 1524w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-800x1075.jpeg 800w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-744x1000.jpeg 744w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-304x409.jpeg 304w, https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module.jpeg 1833w" sizes="(max-width: 520px) 100vw, 520px" data-attachment-id="86418" data-permalink="https://auxomedical.com/?attachment_id=86418" data-orig-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module.jpeg" data-orig-size="1833,2463" data-comments-opened="0" data-image-meta="{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}" data-image-title="Alaris Medley 8015 Point of Care Module" data-image-description="" data-image-caption="" data-large-file="https://auxomedical.com/wp-content/uploads/2016/11/Alaris-Medley-8015-Point-of-Care-Module-762x1024.jpeg" /><a href="https://auxomedical.com/products/alaris-medley-8015/?add-to-cart=2200" aria-describedby="woocommerce_loop_add_to_cart_link_describedby_2200" data-quantity="1" class="button product_type_simple add_to_cart_button ajax_add_to_cart" data-product_id="2200" data-product_sku="AM-Alaris-8015" aria-label="Add to cart: &ldquo;Alaris Medley 8015 Point of Care Module&rdquo;" rel="nofollow" data-success_message="&ldquo;Alaris Medley 8015 Point of Care Module&rdquo; has been added to your cart" role="button">Add to cart</a>	<span id="woocommerce_loop_add_to_cart_link_describedby_2200" class="screen-reader-text">
			</span>
		
    </div><!-- .productimagebox -->
      
	<div class="productcontent">
		<h3><a href="https://auxomedical.com/products/alaris-medley-8015/">Alaris Medley 8015 Point of Care Module</a></h3>

		
	<span class="price"><span class="woocommerce-Price-amount amount"><bdi><span class="woocommerce-Price-currencySymbol">&#36;</span>725.00</bdi></span></span>
The Alaris Medley 8015 Point of Care Module is a versatile, modular infusion and monitoring system designed for adult, pediatric, and neonatal care, providing clinicians with a unified interface for programming and managing multiple channels simultaneously. This compact unit, weighing&hellip;	</div><!-- .productcontent -->

	
