<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Steam Sterilizer &#8211; Auxo Medical</title>
	<atom:link href="https://auxomedical.com/product-tag/steam-sterilizer/feed/" rel="self" type="application/rss+xml" />
	<link>https://auxomedical.com</link>
	<description>New &#38; Refurbished Medical Equipment Sales, Maintenance &#38; Repair</description>
	<lastBuildDate>Sun, 15 Feb 2026 20:32:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://auxomedical.com/wp-content/uploads/2017/06/cropped-imageedit_17_8639328382-32x32.png</url>
	<title>Steam Sterilizer &#8211; Auxo Medical</title>
	<link>https://auxomedical.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">213722008</site>	<item>
		<title>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:44:20 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86350</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</strong> is a high-capacity, gravity-based sterilizer designed for swift, reliable processing of heat- and moisture-stable materials. Featuring a spacious 26" x 37.5" x 48" (767 liters) chamber, it provides ample room to sterilize liquids, media, glassware, instruments, clothing, and laboratory waste efficiently. Equipped with a range of cycle options—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SG-148 offers versatile sterilization tailored to diverse laboratory needs. Its user-friendly features include a fluorescent display, impact printer for cycle documentation, help screens for troubleshooting, and PC connectivity for data management. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it ensures safety and performance. Optional stainless steel side panels are available for added durability, making the SG-148 an excellent choice for demanding scientific applications requiring consistent, high-quality sterilization.</p>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/">Steris AMSCO Century SG-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SG-148 Scientific Steam Sterilizer</h2>
</div>
<div>
<p>Steris SG-148 Scientific Steam Sterilizers are designed for fast, efficient sterilization. The SG-148 gravity sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 48″ (767 Liters) chamber, the SG148 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
</div>
<h2>Features:</h2>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 48″ chamber (767 Liters)</li>
<li>Gravity Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Cabinet Package</li>
<li>Loading Cart</li>
<li>Integral Steam Generator</li>
<li>Water Filtration Options</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<h3>Prevacuum configuration sterilizers are factory programmed with the following cycles:</h3>
<ul>
<li><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</li>
<li><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</li>
<li><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)
<ul>
<li>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</li>
<li>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.</li>
<li>Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
</ul>
</li>
<li><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
<li><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</li>
<li><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</li>
</ul>
</div>
</div>
<h3><u>Utility Requirements:</u></h3>
<ul>
<li><b>Steam</b>
<ul>
<li>1” NPT</li>
<li>50 to 80 psig (3.5 – 5.6 bar) dynamic</li>
<li>97% &#8211; 100% vapor quality</li>
</ul>
</li>
<li><b>Drain</b>
<ul>
<li>2” ODT drain terminal</li>
</ul>
</li>
<li><b>Electrical &#8211; Controls</b>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><b>Electrical–Vacuum Pump</b>
<ul>
<li>208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</li>
<li>480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</li>
</ul>
</li>
<li><b>Sterilizer Feed Water</b>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</li>
</ul>
</li>
</ul>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sg-148-scientific-steam-sterilizer/">Steris AMSCO Century SG-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86350</post-id>	</item>
		<item>
		<title>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:44:10 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86348</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</strong> is a high-capacity, pre-vacuum sterilizer engineered for rapid and reliable sterilization of heat- and moisture-stable materials. Boasting a spacious <strong>26" x 37.5" x 48" (767 liters) chamber</strong>, it accommodates large loads of liquids, media, glassware, instruments, clothing, and laboratory waste. Equipped with multiple cycles—including pre-vacuum, gravity, flash, express, leak test, and daily air removal—the SV-148 provides flexible and thorough sterilization tailored to diverse laboratory needs. Its features include a user-friendly fluorescent display, impact printer for cycle documentation, help screens for troubleshooting, and PC connectivity for data management. Built with a non-lubricated, steam-activated door seal and an emergency manual exhaust valve, it ensures safety and performance. Optional stainless steel side panels are available for added durability. Designed for efficiency and consistency, the SV-148 is ideal for demanding scientific and laboratory applications.</p>
<p>[vc_btn title="<strong>Steris Century Laboratory Sterilizers Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/">Steris AMSCO Century SV-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century SV-148 Scientific Steam Sterilizer</h2>
</div>
<div>
<p>Steris SV-148 Scientific Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The SV-148 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 48″ (767 Liters) chamber, the SV148 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind and designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
</div>
<h2>Features:</h2>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 48″ chamber (767 Liters)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Cabinet Package</li>
<li>Loading Cart</li>
<li>Integral Steam Generator</li>
<li>Water Filtration Options</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<h3>Prevacuum configuration sterilizers are factory programmed with the following cycles:</h3>
<ul>
<li><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</li>
<li><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</li>
<li><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)
<ul>
<li>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</li>
<li>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.</li>
<li>Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
</ul>
</li>
<li><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
<li><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</li>
<li><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</li>
</ul>
</div>
</div>
<h3><u>Utility Requirements:</u></h3>
<ul>
<li><b>Steam</b>
<ul>
<li>1” NPT</li>
<li>50 to 80 psig (3.5 – 5.6 bar) dynamic</li>
<li>97% &#8211; 100% vapor quality</li>
</ul>
</li>
<li><b>Drain</b>
<ul>
<li>2” ODT drain terminal</li>
</ul>
</li>
<li><b>Electrical &#8211; Controls</b>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><b>Electrical–Vacuum Pump</b>
<ul>
<li>208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</li>
<li>480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</li>
</ul>
</li>
<li><b>Sterilizer Feed Water</b>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</li>
</ul>
</li>
</ul>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Century-Laboratory-Sterilizers.pdf" title="" target="_blank"><strong>Steris Century Laboratory Sterilizers Brochure</strong></a></div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-sv-148-scientific-steam-sterilizer/">Steris AMSCO Century SV-148 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86348</post-id>	</item>
		<item>
		<title>Steris AMSCO SV-116 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 21:11:58 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86343</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO SV-116 Scientific Steam Sterilizer</strong> is a high-performance, pre-vacuum sterilizer designed for reliable sterilization of nonporous, heat- and moisture-stable laboratory items. With a spacious <strong>16" x 16" x 26" (109 liters)</strong> chamber, it accommodates a variety of laboratory applications, including sterilization of liquids, media, glassware, instruments, clothing, and waste. The unit features a user-friendly fluorescent display, an impact printer for cycle documentation, and a touch screen interface for easy operation and troubleshooting. Built as a freestanding vertical door model, it includes a rack and two shelves, an emergency manual exhaust valve, and a non-lubricated, steam-activated door seal for efficient performance. Certified to UL, CSA, and ASME standards, with a maximum operating temperature of 250º to 270ºF, the SV-116 offers fast, efficient sterilization with high accountability, making it ideal for demanding laboratory environments.</p>
<p>[vc_btn title="<strong>Steris Amsco Century Small Scientific Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/">Steris AMSCO SV-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Steris AMSCO SV-116 Scientific Steam Sterilizer</h3>
<p>Steris AMSCO SV-116 Pre-vacuum Steam Sterilizer is designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>16″ x 16″ x 26″ chamber (109 Liters)</li>
<li>Rack and 2 shelves</li>
<li>Freestanding unit</li>
<li>Vertical Door</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
</ul>
<h3>Specifications:</h3>
<ul>
<li>Chamber Size: 16&#8243; x 16&#8243; x 26” (109 Liters)</li>
<li>Overall Exterior Dimensions (including door lock-wheel): 74.5&#8243;H x 30&#8243;W x 35.75&#8243;D (with door closed)</li>
<li>Operating Temperature: 250º to 270º</li>
<li>One (1) Rack, Two (2) Shelves</li>
<li>Touch Screen Display</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf" title="" target="_blank"><strong>Steris Amsco Century Small Scientific Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sv-116-scientific-steam-sterilizer/">Steris AMSCO SV-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86343</post-id>	</item>
		<item>
		<title>Steris AMSCO SG-116 Scientific Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-sg-116-scientific-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 12 Jan 2026 16:35:15 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86319</guid>

					<description><![CDATA[<p>The <strong>Steris AMSCO SG-116 Scientific Steam Sterilizer</strong> is a <strong>gravity-based sterilizer</strong> designed for the rapid sterilization of nonporous, heat- and moisture-stable goods, liquids, and media in life sciences and research settings. It features a <strong>16" x 16" x 26" (109 L)</strong> chamber, a freestanding vertical-door design, and supports standard gravity sterilization cycles with fast, efficient processing. Highlights include a fluorescent display and ink-on-paper impact printer for clear readouts, an emergency manual exhaust valve, and a non-lubricated, steam-activated door seal. The unit comes with a rack and two shelves, a touch screen display for easy programming and troubleshooting, and external dimensions of approximately 74.5" H x 30" W x 35.75" D, making it a compact solution for research and life sciences applications.</p>
<p>[vc_btn title="<strong>Steris Amsco Century Small Scientific Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sg-116-scientific-steam-sterilizer/">Steris AMSCO SG-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Steris AMSCO SG-116 Scientific Steam Sterilizer</h3>
<p>Steris AMSCO SG-116 Gravity Steam Sterilizer is designed for sterilization of nonporous heat- and moisture-stable goods, sterilization of liquids and media applications. <span class="TextRun Highlight SCXW118204499 BCX8" lang="EN-US" xml:lang="EN-US" data-contrast="none"><span class="NormalTextRun SCXW118204499 BCX8">This laboratory steam sterilizer provides high quality repeatable performance and accountability for a wide range of lab applications, </span><span class="NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW118204499 BCX8">including:</span><span class="NormalTextRun SCXW118204499 BCX8"> liquids, media, glassware, instruments, clothing, waste, media clothing and laboratory items.</span></span><span class="EOP SCXW118204499 BCX8" data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>16″ x 16″ x 26″ chamber (109 Liters)</li>
<li>Rack and 2 shelves</li>
<li>Freestanding unit</li>
<li>Vertical Door</li>
<li>Gravity Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
</ul>
<h3>Specifications:</h3>
<ul>
<li>Chamber Size: 16&#8243; x 16&#8243; x 26” (109 Liters)</li>
<li>Overall Exterior Dimensions (including door lock-wheel): 74.5&#8243;H x 30&#8243;W x 35.75&#8243;D (with door closed)</li>
<li>Operating Temperature: 250º to 270º</li>
<li>One (1) Rack, Two (2) Shelves</li>
<li>Touch Screen Display</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2026/01/Steris-Amsco-Century-Small-Scientific-Technical-Brochure.pdf" title="" target="_blank"><strong>Steris Amsco Century Small Scientific Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-sg-116-scientific-steam-sterilizer/">Steris AMSCO SG-116 Scientific Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86319</post-id>	</item>
		<item>
		<title>Steris AMSCO C Series 20&#8243; Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-c-series-20-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 06 Jan 2026 18:16:20 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=86302</guid>

					<description><![CDATA[<p>The <strong>Steris C Series 20" Sterilizer</strong> is a expertly refurbished small steam sterilizer, expertly refurbished to meet OEM standards and upgraded to comply with the latest AAMI requirements. Designed for quick and efficient sterilization of heat- and moisture-stable materials, it is ideal for healthcare facilities needing reliable sterilization of items for immediate use. This sterilizer features an advanced AMSCO C Series control system with a user-friendly touch screen, providing easy programming, troubleshooting, and alarm management. Its vertical sliding door is hands-free, operated via a foot pedal, and equipped with a steam-activated, non-lubricated door seal for added dependability. Built with a modular vessel and piping system, it maximizes on-time performance and reliability. The sterilizer includes cycles such as prevacuum, gravity, leak test, and daily air removal, with an optional SFPP configuration for enhanced sterilization options. Compact and efficient, its interior dimensions are 20" x 20" x 38" (508 x 508 x 965 mm), making it a dependable solution for maintaining sterile processing in healthcare environments.</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-c-series-20-sterilizer/">Steris AMSCO C Series 20&#8243; Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Steris C Series 20&#8243; Sterilizer</h2>
<p>AMSCO C Series Refurbished Small Steam Sterilizers are designed for sterilization of materials used in healthcare facilities. The sterilizers are refurbished to OEM specifications and upgraded to meet the most current standards of the Association for the Advancement of Medical Instrumentation (AAMI). The sterilizers are designed for fast, efficient sterilization of heat- and moisture-stable materials in addition to sterilization of items for immediate use. AMSCO C Series small sterilizers are equipped with prevacuum, gravity, leak test and daily air removal test cycles. An optional Steam Flush Pressure Pulse (SFPP) configuration sterilizer adds SFPP cycles.</p>
<h3>FEATURES:</h3>
<ul>
<li><strong>AMSCO C Series control system with enhanced functionality and user-friendly interface screen.</strong>
<ul>
<li>Touch-sensitive screen with 30-line x 40-character display area</li>
<li>Ink-on-paper impact printer</li>
<li>Help screens for programming and troubleshooting alarm conditions</li>
<li>Automatic check of control program and cycle data maintains process integrity</li>
<li>Service reprogrammable flash ROM memory</li>
</ul>
</li>
<li><strong>Vertical sliding door with hands-free loading and unloading capability.</strong>
<ul>
<li>Foot pedal activated door opening and closing</li>
<li>Non lubricated, steam-activated door seal</li>
</ul>
</li>
<li><strong>Modularized vessel and piping for increased dependability and maximum up time.</strong>
<ul>
<li>Reduced piping components increase reliability</li>
<li>Emergency manual exhaust valve</li>
<li>Electronic water saving control</li>
</ul>
</li>
<li><strong>Interior Dimensions</strong>
<ul>
<li> 20&#8243; x 20&#8243; x 38&#8243; (508 x 508 x 965 mm)</li>
</ul>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-c-series-20-sterilizer/">Steris AMSCO C Series 20&#8243; Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">86302</post-id>	</item>
		<item>
		<title>Steris 400 Series 36&#8221; House Steam Sterilizer Recessed</title>
		<link>https://auxomedical.com/products/steris-400-series-36-house-steam-sterilizer-recessed/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 25 Aug 2025 14:28:58 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=85810</guid>

					<description><![CDATA[<p>The <strong>Steris 400 Series 36" House Steam Sterilizer is a recessed</strong>, high-volume sterilization solution designed for efficiency and reliability. Its <strong>interior chamber measures 26 x 37.5 x 36 inches</strong>, with a fast, low-effort hinged-door option that locks or unlocks in a single 30-degree motion. A robust vacuum pump pulls the chamber to precise vacuum levels to save water, while steam is delivered at 1" NPT with 50–80 psig (3.5–5.6 bar) and vapor quality of 97%–100%. The unit features a 2" ODT drain and a 1" NPT water feed for vacuum, heat exchanger, and trap cooling, all powered by configurable electrical options to suit your facility. Every processing cycle is factory-programmed and validated to AAMI ST8, and the sterilizer meets UL 61010-1, CAN/CSA-C22.2 61010-1, and ASME Section VIII Division 1 standards, ensuring compliance and safety. With durable construction rated for 45 psig working pressure and ETL-certified components, this Steris sterilizer delivers dependable performance for high-demand clinical environments.</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-400-series-36-house-steam-sterilizer-recessed/">Steris 400 Series 36&#8221; House Steam Sterilizer Recessed</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Steris 400 Series 36&#8221; House Steam Sterilizer Recessed</h2>
<h3>Product Configurations</h3>
<ul>
<li><strong>Interior Chamber Dimensions</strong>
<ul>
<li><strong>26 x 37.5 x 36&#8243;</strong></li>
<li>26 x 37.5&#8243; chamber cross-sections are sized for efficient, high-volume sterilization processing. Fast-operating, low-effort manual door lock mechanism (hinged-door models) allows door to be locked or unlocked using a single 30° handle motion.</li>
</ul>
</li>
<li><strong>Vacuum pump</strong> effectively pulls chamber to specified vacuum levels and reduces water consumption.</li>
<li><strong>Steam</strong>
<ul>
<li>1&#8243; NPT, 50 to 80 psig (3.5 to 5.6 bar) dynamic, 97% to 100% vapor quality.</li>
</ul>
</li>
<li><strong>Drain</strong>
<ul>
<li>2&#8243; ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to Utilities Consumption, page 6.)</li>
</ul>
</li>
<li><strong>Electrical – Controls</strong>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><strong>Electrical – Vacuum Pump</strong>
<ul>
<li>208/240 Vac, 50/60 Hz, 3-phase, 6 Amp per phase</li>
<li>380/415 Vac, 50/60 Hz, 3-phase, 3 A per phase</li>
<li>480 Vac, 50/60 Hz, 3-phase, 3 Amp per phase</li>
</ul>
</li>
<li><strong>Sterilizer Feed Water</strong>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling. Refer to Water Quality Recommendations listed on page 6 of technical data sheet</li>
</ul>
</li>
</ul>
<p><strong>All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8.</strong></p>
<p>Each sterilizer meets the applicable requirements of the following listings and standards, and carries the appropriate symbols:</p>
<ul>
<li>Underwriters Laboratory (UL) Standard 61010-1 as certified by ETL Testing Laboratories, Inc.</li>
<li>CAN/CSA-C22.2 No. 61010-1.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form U-1 is provided with shipment. Shell and door are constructed to withstand working pressure of 45 psig.</li>
</ul>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-400-series-36-house-steam-sterilizer-recessed/">Steris 400 Series 36&#8221; House Steam Sterilizer Recessed</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">85810</post-id>	</item>
		<item>
		<title>Tuttnauer Model 69B-SCP Pre-Vac Steam Sterilizer</title>
		<link>https://auxomedical.com/products/tuttnauer-model-69b-scp-pre-vac-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Mon, 25 Mar 2024 19:28:23 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/?post_type=product&#038;p=81707</guid>

					<description><![CDATA[<p>The <strong>Tuttnauer Model 69B-SCP Pre-Vac Steam Sterilizer</strong> boasts an impressive array of features designed to meet the rigorous sterilization needs of modern laboratories and medical facilities. With its spacious internal chamber dimensions of 24"W x 36"H x 48"D, this free-standing unit is encased in a durable stainless steel cabinet and comes equipped with a single, automatic hinged door for ease of use. It utilizes house-supplied steam within a 50-80 PSI range and is controlled by a BacSoft microprocessor featuring a 7” color touch screen for intuitive operation. The sterilizer offers a variety of cycles, including Gravity, Liquid, and Pre-Vac, along with essential test cycles like Vacuum Leak and Bowie Dick Tests, ensuring high sterilization standards are consistently met. Its construction includes stainless steel threaded piping, with components made from brass and stainless steel, ensuring longevity and reliability. The air-operated valves, liquid ring vacuum pump, and effluent condensate cooler further enhance its performance, while the inclusion of a loading cart and transfer carriage simplifies the handling of materials. Additionally, Tuttnauer provides a reassuring 1-year parts and labor warranty, alongside an extended 15-year warranty on the pressure vessel, underscoring their confidence in the product's quality and durability.</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/tuttnauer-model-69b-scp-pre-vac-steam-sterilizer/">Tuttnauer Model 69B-SCP Pre-Vac Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Tuttnauer Model 69B-SCP Pre-Vac Steam Sterilizer</h3>
<h3><strong>Features:</strong></h3>
<p><strong>Internal Chamber Dimensions:</strong> 24&#8243;W x 36&#8243;H x 48&#8243;D<br />
<strong>Door Configuration:</strong> Single, Automatic Hinged Door<br />
<strong>Steam Supply:</strong> House Supplied (50-80 PSI)<br />
<strong>Mounting:</strong> Free-Standing with Stainless Steel Cabinet<br />
<strong>Controls:</strong> BacSoft Microprocessor with 7” Color Touch Screen<br />
<strong>Printer:</strong> Alphanumeric, Thermal<br />
<strong>Cycles:</strong> Gravity, Liquid, Pre-Vac<br />
<strong>Test Cycles:</strong> Vacuum Leak Test, Bowie Dick Test<br />
<strong>Piping:</strong> Stainless Steel Threaded<br />
<strong>Components:</strong> Brass and Stainless Steel (Non-Proprietary)<br />
<strong>Valves:</strong> Air-Operated Valves<br />
<strong>Air Source:</strong> Air Compressor<br />
<strong>Vacuum System:</strong> Liquid Ring Vacuum Pump (3-Phase Power Required, 208V or 480V)<br />
<strong>Condensate Cooler:</strong> Effluent cooled to below 140 degrees<br />
<strong>Chamber:</strong> 316L Stainless Steel<br />
<strong>Jacket:</strong> 304L Stainless Steel<br />
<strong>Loading Equipment:</strong> Loading Cart and Transfer Carriage Included</p>
<p><strong>Warranty:</strong><br />
1-Year Parts and Labor Warranty<br />
15-Year Pressure Vessel Warranty</p>
<p>Lead time begins after Submittal/Drawing Approvals received by MFG</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/tuttnauer-model-69b-scp-pre-vac-steam-sterilizer/">Tuttnauer Model 69B-SCP Pre-Vac Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">81707</post-id>	</item>
		<item>
		<title>Steris Amsco Eagle 3033 Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-amsco-eagle-3033/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 26 Feb 2019 21:22:43 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/product/steris-amsco-eagle-3033/</guid>

					<description><![CDATA[<p>The refurbished <strong>Steris Amsco Eagle 3033 Steam Sterilizer</strong> offers a large <strong>24" x 36" x 36" chamber</strong> for high-volume sterilization needs. This recess-mountable unit (with optional cabinet package) features the advanced Stage 3 controller with a thermal printer for precise cycle management and documentation. The 3033 model operates as a pre-vacuum sterilizer, while the 3031 variant offers gravity operation. Both models achieve operating temperatures between 250°F and 270°F. A single radial arm manual door (with optional hinge) facilitates easy loading and unloading. The thermal display and touchpad interface provide user-friendly control and monitoring. A hydrostatically tested pressure chamber ensures safe and reliable operation. The refurbishment process involves complete disassembly and rebuilding using original equipment manufacturer (OEM) parts and procedures, guaranteeing quality and performance. Optional stainless steel side panels and a cart are available for enhanced functionality. In-service training is included, and installation services are available at an additional cost.</p>
<p><strong>Models:</strong><br aria-hidden="true" />• Steris Model 3031: Gravity Sterilizer<br aria-hidden="true" />• Steris Model 3033: Pre-vac sterilizer</p>
<p>[vc_btn title="<strong>3000 Stage 3 Cycle information</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/3000-Stage-3-Cycle-information.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"] [vc_btn title="<strong>Amsco Refurb 3000 Medium Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/Amsco-Refurb-3000-Medium-Technical-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-eagle-3033/">Steris Amsco Eagle 3033 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Refurbished Steris Amsco Eagle 3033 Steam Sterilizer</h2>
<p>Refurbished Steris Amsco Eagle 3000 Stage 3 series, 24&#8243;x 36&#8243; x 36&#8243;, single door sterilizer. Recess mounted, or optional cabinet package. Model 3033. Pre-vac sterilizer, (3031 variant for gravity operation) with operating temperature of 250-270F.</p>
<h3>Models:</h3>
<ul>
<li>Steris Model 3031: Gravity Sterilizer</li>
<li>Steris Model 3033: Pre-vac sterilizer</li>
</ul>
<h3>Features:</h3>
<ul>
<li> Stage 3 controller with thermal printer</li>
<li>Single Radial arm manual door (optional hinge)</li>
<li>Recess Mount</li>
<li>Interior chamber size of 24&#8243;x36&#8243;x36&#8243;</li>
<li>Pre-vacuum configuration or Gravity configuration</li>
<li>Thermal display with touch pad operation</li>
<li>Hydrostatically tested pressure chamber</li>
<li>All reconditioned steam sterilizers are fully disassembled and rebuilt using all OEM parts and procedures.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Stainless steel side panels and Cart.</li>
</ul>
<h3>Additional Information:</h3>
<ul>
<li>Refurbished Steris Eagle Sterilizers are fully disassembled and rebuilt using all OEM parts and procedures.</li>
<li>Additional cost for installation of equipment.</li>
<li>In-service training included.</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:<br aria-hidden="true" />
<ul>
<li>Underwriters Laboratories (UL) Standard 61010-1 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 1010.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form U-1 is furnished. Shell and door are designed for maximum allowable working pressure of 45 psig (3.1 bar)</li>
</ul>
</li>
</ul>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/Amsco-Refurb-3000-Medium-Technical-Brochure.pdf" title="" target="_blank"><strong>Amsco Refurb 3000 Medium Technical Brochure</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-eagle-3033/">Steris Amsco Eagle 3033 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6302</post-id>	</item>
		<item>
		<title>Steris AMSCO Century V-148 Steam Sterilizer (148H and G-148)</title>
		<link>https://auxomedical.com/products/steris-amsco-century-v148/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Tue, 26 Feb 2019 21:22:25 +0000</pubDate>
				<guid isPermaLink="false">https://auxomedical.com/product/steris-amsco-century-v148/</guid>

					<description><![CDATA[<p>The S<strong>teris AMSCO Century V-148 Steam Sterilizer (148H and G-148)</strong> is a fast, efficient pre-vacuum steam sterilizer designed for heat- and water-resistant loads, delivering the same capabilities as a gravity model with enhanced processing speed. It features a <strong>26" x 37.5" x 48" (767 L)</strong> chamber and cycles including pre-vacuum, gravity, flash, express, leak test, and daily air removal test. Highlights include a fluorescent display, ink-on-paper impact printer, emergency manual exhaust valve, a non-lubricated, steam-activated door seal, and helpful screens for programming and alarm troubleshooting. The unit offers broad PC communication compatibility, an electronic water conservation valve, and optional stainless steel side panels, with available pre-vacuum and gravity configurations to fit your application.</p>
<p>[vc_btn title="<strong>Century Medium Cycle and Load Data</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/Century-Medium-Cycle-and-Load-Data.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"] [vc_btn title="<b>Century Medium Technical Specifications</b>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/TRUE-MEDIUM-Century-Medium-Maintenance-26-x-37.5-P764330-117-dragged.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"] [vc_btn title="<b>Century Medium Brochure</b>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/Steris-Amsco-Century-Medium-Brochure.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-v148/">Steris AMSCO Century V-148 Steam Sterilizer (148H and G-148)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<h2>Steris AMSCO Century V-148 Steam Sterilizer (148H and G-148)</h2>
</div>
<div>
<p>Steris V-148 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The V148 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 48″ (767 Liters) chamber, the V148 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind.</p>
</div>
<h2>Features:</h2>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>26″ x 37.5″ x 48″ chamber (767 Liters)</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
<li>Communication interface compatibility w/ most PC devices</li>
<li>Electronic water conservation valve</li>
<li>Optional Stainless steel side panels available.</li>
</ul>
<h3>Additional Options:</h3>
<ul>
<li>Cabinet Package</li>
<li>Loading Cart</li>
<li>Integral Steam Generator</li>
<li>Water Filtration Options</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div id="ProductDetail_ProductDetails_div">
<div>
<div>
<h3>Prevacuum configuration sterilizers are factory programmed with the following cycles:</h3>
<ul>
<li><b><u>270°F (132°C) Prevacuum</u></b> (with either 5-minute or 20-minute dry phases) &#8211; For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 5 minutes or 20 minutes</li>
<li><b><u>Gravity, Liquid, 250°F </u></b><b><u>(121°C)</u></b> &#8211; For sterilizing fabrics, Sterilize temperature: 250°F (121°C) &#8211; Sterilize time: 30 minutes &#8211; Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)</li>
<li><b><u>270°F (132°) Gravity Cycle</u></b>: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 15 minutes &#8211; Dry time: 30 minutes (Note: 270°F temperature must be set by the user)
<ul>
<li>SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.</li>
<li>Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.</li>
<li>Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
</ul>
</li>
<li><b><u>WRAP/SFPP Cycle</u></b>: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. &#8211; Sterilize temperature: 270°F (132°C) &#8211; Sterilize time: 4 minutes &#8211; Dry time: 20 minutes</li>
<li><b><u>Liquid Cycle:</u></b> This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) &#8211; Factory programmed sterilize time: 45 minutes &#8211; Dry time: not applicable</li>
<li><b><u>275°F (135°C) Prevacuum Cycle</u></b>: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes</li>
</ul>
</div>
</div>
<h3><u>Utility Requirements:</u></h3>
<ul>
<li><b>Steam</b>
<ul>
<li>1” NPT</li>
<li>50 to 80 psig (3.5 – 5.6 bar) dynamic</li>
<li>97% &#8211; 100% vapor quality</li>
</ul>
</li>
<li><b>Drain</b>
<ul>
<li>2” ODT drain terminal</li>
</ul>
</li>
<li><b>Electrical &#8211; Controls</b>
<ul>
<li>120 Volt, 50/60 Hz, 1-phase, 2.0 Amp</li>
</ul>
</li>
<li><b>Electrical–Vacuum Pump</b>
<ul>
<li>208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.</li>
<li>480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.</li>
</ul>
</li>
<li><b>Sterilizer Feed Water</b>
<ul>
<li>1&#8243; NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.</li>
</ul>
</li>
</ul>
<div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/Century-Medium-Cycle-and-Load-Data.pdf" title="" target="_blank"><strong>Century Medium Cycle and Load Data</strong></a></div> <div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/TRUE-MEDIUM-Century-Medium-Maintenance-26-x-37.5-P764330-117-dragged.pdf" title="" target="_blank"><b>Century Medium Technical Specifications</b></a></div> <div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/Steris-Amsco-Century-Medium-Brochure.pdf" title="" target="_blank"><b>Century Medium Brochure</b></a></div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-amsco-century-v148/">Steris AMSCO Century V-148 Steam Sterilizer (148H and G-148)</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6299</post-id>	</item>
		<item>
		<title>Steris AMSCO V-116 Steam Sterilizer</title>
		<link>https://auxomedical.com/products/steris-v116-steam-sterilizer/</link>
		
		<dc:creator><![CDATA[Auxo Medical]]></dc:creator>
		<pubDate>Thu, 13 Jul 2017 16:37:47 +0000</pubDate>
				<guid isPermaLink="false">http://auxomedical.com/?post_type=product&#038;p=4937</guid>

					<description><![CDATA[<p>The Refurbished <strong>Steris AMSCO Model V-116 Steam Sterilizer</strong> is a compact, fast pre-vacuum sterilizer designed for efficient processing of heat- and moisture-stable loads. It features a 16" x 16" x 26" (110 L) chamber, freestanding vertical-door design, and a rack with two shelves for versatile setup. The unit offers pre-vacuum, gravity, flash, express, leak test, and daily air removal test cycles, delivering reliable sterilization with quick turnaround. Highlights include a fluorescent display and an ink-on-paper impact printer for clear readouts, an emergency manual exhaust valve, a non-lubricated, steam-activated door seal, and helpful screens for programming and troubleshooting. Exterior dimensions are approximately 74.5" H x 30" W x 35.75" D, with an operating range of 250–270°F, making it a dependable option for refurbished sterilization needs in healthcare settings.</p>
<p>[vc_btn title="<strong>True Domestic Small Steris Amsco Century Technical Brochure</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/TRUE-DOMESTIC-Small-Steris-Amsco-Century-Technical-Brochure-copy.pdf &#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>[vc_btn title="<strong>Steris Century Small Drain Location</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/Steris-Century-Small-Drain-Location.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"] [vc_btn title="<strong>Century Small Cycle Data</strong>" style="flat" shape="square" link="url:/wp-content/uploads/2022/02/Century-Small-Cycle-Data.pdf&#124;&#124;target: _blank&#124;" css=".vc_custom_1479498791367{margin-left: 5px !important;padding-right: 0px !important;padding-left: 0px !important;}"]</p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-v116-steam-sterilizer/">Steris AMSCO V-116 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Refurbished Steris AMSCO Model V-116 Steam Sterilizer</h2>
<p>Steris V-116 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The V116 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles.</p>
<h3>Features:</h3>
<ul>
<li>Florescent display for easy reading</li>
<li>Ink on paper impact printer</li>
<li>16″ x 16″ x 26″ chamber (110 Liters)</li>
<li>Rack and 2 shelves</li>
<li>Freestanding unit</li>
<li>Vertical Door</li>
<li>Pre-vacuum Steam Sterilizer</li>
<li>Fast &amp; efficient</li>
<li>Emergency manual exhaust valve</li>
<li>Non-lubricated, steam-activated door seal</li>
<li>Help screens for programming/troubleshooting alarm conditions</li>
</ul>
<h3>Specifications:</h3>
<ul>
<li>Chamber Size: 16&#8243; x 16&#8243; x 26” (110 Liters)</li>
<li>Overall Exterior Dimensions (including door lock-wheel): 74.5&#8243;H x 30&#8243;W x 35.75&#8243;D (with door closed)</li>
<li>Operating Temperature: 250º to 270º</li>
<li>One (1) Rack, Two (2) Shelves</li>
<li>Touch Screen Display</li>
</ul>
<h3>Standards:</h3>
<ul>
<li>Each sterilizer meets applicable requirements of the following listings and standards, and carries the appropriate symbols:
<ul>
<li>Underwriters Laboratories (UL) Standard 544 as certified by ETL Testing Laboratories, Inc.</li>
<li>Canadian Standards Association (CSA) Standard C22.2 No. 125.</li>
<li>ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form R-1 is furnished. Shell and door are designed for maximum allowable working pressure of 42 psig (289.6 kPa) for 16 x 16 x 26&#8243;(406 x 406 x 660 mm) sterilizers and 40 psig (275.8 kPa) for 20 x 20 x 38&#8243; (508 x 508 x 965 mm) sterilizers.</li>
<li>ASME Code, Section I, Part PMB, for power boilers, if optional steam generator is supplied.</li>
<li>Seismic Pre-approval R-0282.</li>
</ul>
</li>
</ul>
<h3><span data-contrast="auto">Breakdown of Prevacuum vs. Gravity</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></h3>
<ul>
<li><b><span data-contrast="none">Gravity</span></b><span data-contrast="none"> - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).</span><br />
<b></b></li>
<li><b><span data-contrast="none">Prevacuum</span></b><span data-contrast="none"> – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.</span></li>
</ul>
<p><strong><em>Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent</em>.</strong></p>
<p>&nbsp;</p>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/TRUE-DOMESTIC-Small-Steris-Amsco-Century-Technical-Brochure-copy.pdf" title="" target="_blank"><strong>True Domestic Small Steris Amsco Century Technical Brochure</strong></a></div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/Steris-Century-Small-Drain-Location.pdf" title="" target="_blank"><strong>Steris Century Small Drain Location</strong></a></div>
<div class="vc_btn3-container vc_btn3-inline vc_custom_1479498791367 vc_do_btn" ><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-square vc_btn3-style-flat vc_btn3-color-skincolor" href="/wp-content/uploads/2022/02/Century-Small-Cycle-Data.pdf" title="" target="_blank"><strong>Century Small Cycle Data</strong></a></div>
<p>The post <a rel="nofollow" href="https://auxomedical.com/products/steris-v116-steam-sterilizer/">Steris AMSCO V-116 Steam Sterilizer</a> appeared first on <a rel="nofollow" href="https://auxomedical.com">Auxo Medical</a>.</p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4937</post-id>	</item>
	</channel>
</rss>