Steris AMSCO Stage 3 Series 16″ 3013 Sterilizer

Request Quote

The Steris AMSCO Stage 3 Series 16″ (Model 3013) Sterilizer is a refurbished steam sterilizer designed for reliable sterilization in healthcare settings. It features a Stage 3 controller with an integrated thermal printer for accurate cycle documentation, and it is configured for recess mounting to optimize space. The sterilizer’s chamber measures 16 inches by 16 inches by 26 inches (110 L), accommodating a variety of sterilization loads. Equipped with a pre-vacuum (Class B) cycle, it ensures thorough sterilization of heat- and moisture-stable materials. The unit includes a thermal display with touchpad operation for easy cycle management and is hydrostatically tested to ensure pressure integrity. Backed by a comprehensive warranty—1 year parts and labor, 6 months on preventive maintenance parts, and 5 years on the pressure vessel—this sterilizer offers dependable performance for your sterilization needs.

To submit a quote request for this product please fill out the form below.
Product Quote Request
Name
Name
Quantity *

SKU: AM-3013 Category: Tags: , , , Brand: ,

Description

Steris AMSCO Stage 3 Series 16″ 3013 Sterilizer

Refurbished Steris Amsco Model 3013 Steam Sterilizer includes: Stage 3 Controller with thermal printer, For Recess Mount, Chamber DIMS 16 x 16 x 26, Prevacuum (Class B), Thermal display with touchpad operation.

Features:

  • Stage 3 controller with thermal printer
  • Single Radial arm manual door (optional hinge)
  • Recess Mount
  • Interior chamber size of 16″ x 16″ x 26″
  • Pre-vacuum configuration
  • Thermal display with touch pad operation
  • Hydrostatically tested pressure chamber

Warranty: 1 Year Parts & Labor, 6 months on PM Parts, 5 years on pressure vessel.

Additional Information:

  • All refurbished steam sterilizers are fully disassembled and rebuilt using all OEM parts and procedures.
  • Optional Stainless steel side panels available.
  • Optional 30kW steam generator for electrical units.
  • Standard Preventative Maintenance must be completed while unit is under warranty
  • Additional freight and installation charges apply.

 

What is the difference between the two configurations: Gravity & Prevacuum?

  • Gravity - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).
  • Prevacuum – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.

Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent.

 

Utility Requirements:

All utility supplies should have manual shutoffs located where the sterilizer connects to the utilities. Any utilities supplied above the sterilizer should be directed downward.

Cold Water (C)
  • 80° F (26.7° C) maximum.
  • A 1” minimum NPT fitting should be provided.
  • Vacuum Sterilizer (3013 & 3023):
  • 30 to 50 minimum dynamic/static psig (206.8 – 344.7 kPa)
  • Peak consumption is 15 GPM; Average consumption is 164 GPH.
Cold Water (C) for Unit with Reimers Steam Generator
  • ½” NPT
  • 20 to 50 psig (137.9 – 344.7 kPa) dynamic
  • Refer to recommended quality under cold water listing.
Steam (S) (House-Steam Units only)
  • A steam trap should be installed in the line immediately upstream of the utility shutoff.
  • A ½” NPT fitting should be available.
  • 50-80 psig (344.7 – 551.6 kPa) dynamic/static
Drain (D)
  • 1- ½” ODT drain terminal and floor drain capable of handling peak water consumption.
  • The drain line must be connected to a receiver capable of withstanding 140° F water otherwise a drain cooler will be required.
Electricity (E)
  • Outlet box for 120 VAC, 50/60 Hz, 1 Amp (5.5 Amps for electric units) electric service to the sterilizer controls.
Generator Electricity (G) (Electric Units only)
  • Steam Generator
  • Outlet box for 120 VAC, 60 HZ, 7 Amp electrical service for the steam generator control.
  • Terminal box for 208 or 480 Volt, 50/60 Hz, 3-phase service to the optional integral electric steam generator heaters.
All configurations require a ground.