Steris 400 Series 36” House Steam Sterilizer Recessed

Request Quote

The Steris 400 Series 36″ House Steam Sterilizer is a recessed, high-volume sterilization solution designed for efficiency and reliability. Its interior chamber measures 26 x 37.5 x 36 inches, with a fast, low-effort hinged-door option that locks or unlocks in a single 30-degree motion. A robust vacuum pump pulls the chamber to precise vacuum levels to save water, while steam is delivered at 1″ NPT with 50–80 psig (3.5–5.6 bar) and vapor quality of 97%–100%. The unit features a 2″ ODT drain and a 1″ NPT water feed for vacuum, heat exchanger, and trap cooling, all powered by configurable electrical options to suit your facility. Every processing cycle is factory-programmed and validated to AAMI ST8, and the sterilizer meets UL 61010-1, CAN/CSA-C22.2 61010-1, and ASME Section VIII Division 1 standards, ensuring compliance and safety. With durable construction rated for 45 psig working pressure and ETL-certified components, this Steris sterilizer delivers dependable performance for high-demand clinical environments.

To submit a quote request for this product please fill out the form below.
Product Quote Request
Name
Name
Quantity *

Description

Steris 400 Series 36” House Steam Sterilizer Recessed

Product Configurations

  • Interior Chamber Dimensions
    • 26 x 37.5 x 36″
    • 26 x 37.5″ chamber cross-sections are sized for efficient, high-volume sterilization processing. Fast-operating, low-effort manual door lock mechanism (hinged-door models) allows door to be locked or unlocked using a single 30° handle motion.
  • Vacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption.
  • Steam
    • 1″ NPT, 50 to 80 psig (3.5 to 5.6 bar) dynamic, 97% to 100% vapor quality.
  • Drain
    • 2″ ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to Utilities Consumption, page 6.)
  • Electrical – Controls
    • 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp
  • Electrical – Vacuum Pump
    • 208/240 Vac, 50/60 Hz, 3-phase, 6 Amp per phase
    • 380/415 Vac, 50/60 Hz, 3-phase, 3 A per phase
    • 480 Vac, 50/60 Hz, 3-phase, 3 Amp per phase
  • Sterilizer Feed Water
    • 1″ NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling. Refer to Water Quality Recommendations listed on page 6 of technical data sheet

All processing cycles factory programmed into the sterilizer control have been validated to AAMI ST8.

Each sterilizer meets the applicable requirements of the following listings and standards, and carries the appropriate symbols:

  • Underwriters Laboratory (UL) Standard 61010-1 as certified by ETL Testing Laboratories, Inc.
  • CAN/CSA-C22.2 No. 61010-1.
  • ASME Code, Section VIII, Division 1 for unfired pressure vessels. The pressure vessel is so stamped; ASME Form U-1 is provided with shipment. Shell and door are constructed to withstand working pressure of 45 psig.