Steris AMSCO LAB110 Steam Sterilizer

Request Quote

The Steris AMSCO LAB110 Steam Sterilizer is a compact life sciences workstation built for safe, reliable sterilization in research settings. It features a 16″ x 16″ x 26″ (110 L) interior with a vertical sliding door and non-lubricated, steam-activated seal, plus a resilient vessel design and reduced piping for dependability and easier service. The operator panel showcases a touch-sensitive, color TFT display with 18-bit color graphics, a 320 x 240 resolution, human-centered symbols, and a CF card slot for memory backup/restore, while offering up to 20 programmable cycles including gravity, prevacuum, isothermal, and liquid cycles tailored to heat- and moisture-stable goods, liquids, and media. Additional conveniences include an emergency manual exhaust valve, a non-clogging chamber drain, a reprogrammable flash memory for controls, and a touch-screen interface with built-in help screens, making the LAB110 a versatile, user-friendly option for scientific sterilization.

 

To submit a quote request for this product please fill out the form below.
Product Quote Request
Name
Name
Quantity *

SKU: AM-LAB110 Category: Tags: , , Brand: ,

Description

Steris AMSCO LAB110 Steam Sterilizer

For proper and safe sterilization in life sciences and research applications

Features:

  • Touch-sensitive screen with 18-bit color graphic display
  • The display features 320 x 240 resolution color-active matrix (TFT)
  • Display is designed with emphasis on human factors and user recognizable symbols
  • 20 cycles may be individually selected and programmed
  • Compact Flash (CF-Card) memory card slot on operator panel for memory backup/restore
  • Help screens for control operation
  • Service reprogrammable flash ROM memory
  • Program is stored in flash for permanent storage
  • Variables are stored in flash memory for permanent storage

Vertical sliding door with manual operation.

  • Non-lubricated, steam activated door seal

Modularized vessel and piping for increased dependability and reduced servicing time.

  • Reduced piping components increase reliability
  • Vessel design allows higher operating temperature (141°C [285°F])
  • Non-clogging chamber drain line prevents media from plugging drain line
  • Emergency manual exhaust valve
  • Interior Chamber Dimensions: 16″x16″x26″ (110L)

Sterilizer is factory-programmed with the following applicable sterilizing cycles:

  • Gravity Cycle, provided on gravity, prevacuum, and isothermal sterilizers, for the sterilization of heat- and moisture-stable goods at 100°C to 141°C (212°F to 285°F), and decontamination of bagged non bio-hazardous laboratory wastes. Gravity cycle utilizes the gravity air- displacement principle.
  • Liquid Cycle, provided on gravity, prevacuum, and isothermal sterilizers, for the sterilization of liquids and media in vented borosilicate glass or metal containers at 100°C to 135°C (212°F to 275°F). Liquid cycle utilizes the optimal solution cooling feature, during exhaust (cooling) phase, to control the exhaust rate.
  • Prevacuum Cycle, provided only on the prevacuum sterilizer, for efficient, high-volume sterilization of porous, heat- and moisture-stable materials at 100°C to 141°C (212°F to 285°F). Prevacuum cycle utilizes a mechanical air- evacuation system.

Breakdown of Prevacuum vs. Gravity 

  • Gravity - designed for sterilization of liquids in flasks with vented closures, at 250°F (121°C), and also heat- and moisture-stabile goods at 270°F (132°C).
  • Prevacuum – designed for efficient, high-volume processing of heat- and moisture-stabile materials, such as fabrics, wrapped hard goods, glassware or animal bedding, at 270°F (132°C). Prevacuum units will also run gravity-type cycles.

Gravity units operate by the gravity downward displacement air-removal principle. Prevacuum sterilizers have a chamber evacuation system for high-speed, high-volume sterilization. Both types use steam-under-pressure as the sterilizing agent.

UTILITY REQUIREMENTS

Sterilizer Using “House” Steam Steam

1/2″ NPT, 50 to 80 psig (344.7 to 551.6 kPa) dynamic, 97 to 100% vapor quality.

Drain

1-1/2″ ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to engineering data.)

Electrical – Controls

120 Volt, 50/60 Hz, 1-phase, 3.0 Amps.

International:

230 Volt, 50/60 Hz, 1-Ph, 1.5 Amps.

Sterilizer Feed Water

1.0″ NPT, 30 to 50 psig (206.8 to 344.7 kPa) dynamic. Water is used for ejectors, vacuum pumps, exhaust condensers, and trap cooling. Refer to Table 1 for recommended water quality. Use of feed water within the nominal conditions will optimize equipment performance and reduce maintenance.

NOTE: Backflow prevention is not provided by STERIS unless backflow preventer option is selected.

Sterilizer Equipped With Integral Carbon Steel Steam Generator

Drain

1-1/2″ ODT drain terminal. (Floor drain capacity must handle peak water consumption; refer to engineering data.)

Generator Drain

1/2″ ODT.

Electrical – Controls

120 Volt, 50/60 Hz, 1-phase, 9.5 Amps.

International:

230 Volt, 50/60 Hz, 1-Ph, 1.5 Amps.

Electrical – Generator

208 Volt, 50/60 Hz, 3-phase, 83.2 Amps; 240 Volt, 50/60 Hz, 3-phase, 72.2 Amps; or 480 Volt, 50/60 Hz, 3-phase, 37 Amps.

International:

380/415 Volt, 50/60 Hz, 3-Ph, 41/45 Amps (Prevacuum Units).

Sterilizer Feed Water

1.0″ NPT, 30 to 50 psig (206.8 to 344.7 kPa) dynamic. Refer to Table 1 for water specification guidelines.

Steam Generator Feed Water

1/2″ NPT, 20 to 50 psig (137.9 to 344.7 kPa) dynamic. Refer to Table 2 for required water quality. Use of feed water within the nominal conditions will optimize equipment performance and reduce maintenance.

Model #:

LAB250, LG-250, LV-250, 250LS

 