Refurbished Steris Century V136 Steam Sterilizer

Steris V136 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The V136 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 36″ chamber, the V136 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind.

Refurbished Steris Century V136 Steam Sterilizer

To submit a quote request for this product please fill out the form below.
Product Quote Request
Name
Name
Quantity *

SKU: AM-V136 Category: Tags: ,

Description

Refurbished Steris Century V136 Steam Sterilizer

Steris V136 Steam Sterilizers are designed for fast, efficient sterilization of heat and water-resistant materials with the same capabilities as a gravity sterilizer. The V136 pre-vacuum sterilizer is equipped with pre-vac, gravity, flash, express, leak test, and daily air removal test cycles. With a 26″ x 37.5″ x 36″ chamber, the V136 sterilizer provides enough space fit all of your equipment and sterilize with speed and reputable quality in mind.

Features:
Florescent display for easy reading
Ink on paper impact printer
26″ x 37.5″ x 36″ chamber
Pre-vacuum Steam Sterilizer
Fast & efficient
Emergency manual exhaust valve
Non-lubricated, steam-activated door seal
Help screens for programming/troubleshooting alarm conditions
Communication interface compatibility w/ most PC devices
Electronic water conservation valve
Optional Stainless steel side panels available.

Additional Options: Cabinet Package, Loading Cart, Integral Steam Generator, Water Filtration Options

Interior Chamber Dimensions:

  • 26″ x 37.5″ x 36″ (660 x 950 x 910 mm)

Vacuum Pump Electric Service:

  • 208/240 VAC, 60 Hz, 3-Phase, 6A per phase
  • 480 VAC, 60 Hz, 3-Phase, 3A per phase

Prevacuum configuration sterilizers are factory programmed with the following cycles:

270°F (132°C) Prevacuum (with either 5-minute or 20-minute dry phases) – For efficient, high volume processing of heat- and moisture-stable materials, such as fabrics and wrapped hard goods. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. Sterilize temperature: 270°F (132°C) – Sterilize time: 4 minutes – Dry time: 5 minutes or 20 minutes

Gravity, Liquid, 250°F (121°C) – For sterilizing fabrics, Sterilize temperature: 250°F (121°C) – Sterilize time: 30 minutes – Dry time: 15 minutes (Note: A gravity cycle, adjusted to 270°F for 25-minute sterilize exposure time, can be used for processing fabric packs.)

270°F (132°) Gravity Cycle: For sterilizing hard goods. Sterilize temperature: 270°F (132°C) – Sterilize time: 15 minutes – Dry time: 30 minutes (Note: 270°F temperature must be set by the user)

SFPP configuration sterilizers are factory programmed with the following cycles: WRAP/SFPP, SFPP, Prevacuum, Gravity, Liquid and Test Cycles.

Note: SFPP Cycle: For efficient, high-volume processing of porous loads. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization.
Sterilize temperature: 270°F (132°C) – Sterilize time: 4 minutes – Dry time: 20 minutes

WRAP/SFPP Cycle: For efficient, high-volume processing of heat- and moisture-stable materials, such as double wrapped instrument trays. This process incorporates a series of steam flushes and pressure pulses at pressures above atmospheric levels to condition load prior to sterilization. – Sterilize temperature: 270°F (132°C) – Sterilize time: 4 minutes – Dry time: 20 minutes

Liquid Cycle: This cycle is used for sterilizing liquids in borosilicate containers with vented closures. » Sterilize temperature: 250°F (121°C) – Factory programmed sterilize time: 45 minutes – Dry time: not applicable

275°F (135°C) Prevacuum Cycle: This cycle is used for efficient, high-volume processing of heat- and moisturestable materials in double-wrapped instrument trays. This process incorporates a series of pressure/vacuum pulses to condition the load prior to sterilization. » Sterilize temperature: 275°F (135°C) » Sterilize time: 3 minutes » Dry time: 16 minutes

Utility Requirements

Steam

• 1” NPT
• 50 to 80 psig (3.5 – 5.6 bar) dynamic
• 97% – 100% vapor quality
Drain
• 2” ODT drain terminal
Electrical – Controls

• 120 Volt, 50/60 Hz, 1-phase, 2.0 Amp

Electrical–Vacuum Pump

• 208/240 Volt, 50/60 Hz, 3-phase, 6 Amp per phase.

• 480 Volt, 50/60 Hz, 3-phase, 3 Amp per phase.
Sterilizer Feed Water
1″ NPT, 20 to 50 psig (1.4 to 3.5 bar) dynamic. Water is used for vacuum pump, heat exchanger and trap cooling.