Description
Reimers SAR 4 kW STAINLESS STEEL SERIES ELECTRIC STEAM BOILER Pump Feed
Features:
- Miniature boiler max. vessel volume 0.29 3
- Maximum safety valve se ng 100psi
- All boilers are manufactured in accordance with the requirements of the A.S.M.E. Boiler and Pressure Vessel Code and A.S.M.E. CSD‐1. Each boiler bears the National Board Stamp “M”
- Dry pure saturated steam, operating pressure range 0 – 85psig
- Heavy duty 316 stainless steel pressure vessel. Vessel jacket and electrical enclosure 304 stainless steel
- Pacified pressure vessel and heating elements
- Standard Equipment of Each Boiler Includes:
- A.S.M.E. pressure relief valve
- One (1) quick opening bottom blowoff valve as per A.S.M.E. Code B31.1
- stainless steel steam outlet ball valve
- High pressure feed pump on ARH‐models
- Low water cutoff control with manual reset
- One (1) high pressure cutoff control with manual reset
- One (1) operating pressure control
- Magnetic contactor
- Indicator lights for POWER, REFILLING, HEATING and ALARMS
Specs:
- 13.6 lbs/hr Steam output
- 240V 1Ph 16.7A
- Operating Pressure Range 0-85psi
- 100psi Safety Relief Valve Setting
- Shipping Weight: 90lbs