Description
Features
 • Vertical boiler design; very low floor space requirements
 • Miniature boiler max. vessel volume 5ft3
 • Maximum safety valve setting 100psi
 • All boilers are manufactured in accordance with the requirements of the A.S.M.E. Boiler and Pressure Vessel Code and A.S.M.E. CSD-1. Each boiler bears the National Board Stamp “M”.
 • Operating pressure range 0 – 85psig
 • Heavy duty carbon steel pressure vessel. Vessel jacket and electrical enclosure powder coated (all 304 stainless steel optional)
Standard Equipment of Each Boiler Includes:
 • A.S.M.E. pressure relief valve
 • High pressure cutoff control with manual reset
 • One (1) operating pressure control for all models
 equipped with two heating elements or two (2) staged operating pressure controls for all models equipped with three or four heating elements
 • Low water level cutoff control with manual reset
 • High water level cutoff control with automatic or
 manual reset.
 • Magnetic contactors
 • Internal branch circuit fusing
 • Enable/Disable switch for each heating element
 • Main supply power distribution block
 • Indicator lights for POWER, REFILLING, HEATING and
 ALARMS
Output: 307.5 lb/hr
 820lb ship weight
Dimensions:
 Width: 28″ x Depth 37.5″x H 54.3″
Service Clearance – 36” on front (for element removal)
 18” recommended remaining 3 sides
 
 