Reliable Steam for Sterile Processing, Labs, and Clinics: Boilers & Steam Generators by Auxo Medical
Clean, dependable steam is the backbone of sterile processing and laboratory workflows. From autoclaves and washer-disinfectors to lab humidification and cage washers, your team needs consistent, medical-grade steam to keep instruments safe and schedules on track. Auxo Medical supplies and supports compact steam generators, boilers, and the critical accessories that complete your steam system—backed by installation, preventive maintenance, and responsive service.
What we offer in Boilers & Steam Generators
Auxo Medical’s portfolio covers the full steam path—from generation to distribution and return—so your facility gets a right-sized, code-compliant solution that fits your space, budget, and demand.
-
Electric steam generators (healthcare-grade)
- Fast-start, compact units ideal for autoclaves and washer-disinfectors
- Clean, quiet operation with simplified utilities
- Staged or modulating elements for stable pressure and efficient turndown
-
Packaged steam boilers
- Options to support higher throughput or multiple sterilizers
- Vertical and horizontal configurations to match mechanical-room constraints
- Integrated controls for reliable pressure and temperature management
-
Skid-mounted systems and turnkey packages
- Factory-assembled for quick install and small footprints
- Pre-piped with feedwater, controls, and safety components to reduce on-site work
-
Boiler feed and condensate return systems
- ASME-rated tanks and high-reliability pumps
- Improves efficiency, stabilizes water temperature, and protects the boiler
-
Blowdown and steam-quality accessories
- Blowdown separators, sample coolers, steam separators, and strainers
- Protects equipment, maintains TDS levels, and supports verification
-
Water treatment and quality solutions
- Softening, filtration, and RO/DI integration to meet sterilization standards
- Reduces scaling, corrosion, and downtime while improving steam quality
-
Controls and distribution components
- Pressure-reducing valves, safety reliefs, steam traps, and regulators
- Properly sized and installed for safe, efficient operation
Why reliable, clean steam matters in healthcare
- Sterilization outcomes: Clean, dry, saturated steam with minimal non-condensable gases is critical for consistent sterilization cycles.
- Asset protection: Proper water quality and blowdown reduce scale and corrosion, extending the life of sterilizers and boilers.
- Throughput and uptime: Right-sized steam generation eliminates pressure dips during peak case loads, reducing cycle aborts and delays.
- Compliance: Proper documentation, testing, and maintenance help meet accreditation and regulatory requirements.
How to choose the right steam solution
Every facility’s steam profile is unique. Auxo Medical helps you evaluate demand, available utilities, codes, and budget to select the best-fit system.
Key considerations:
- Load profile: Number and size of sterilizers/washer-disinfectors, cycle concurrency, and peak vs. base load
- Utilities: Electrical service (voltage/phase), gas availability, makeup water quality, and drain capacity
- Steam quality: Requirements for dryness, pressure stability, and non-condensable gas control
- Space and access: Mechanical room layout, ventilation, and service clearances
- Compliance and safety: ASME, local/state boiler codes, and healthcare accreditation standards
- Redundancy and growth: N+1 strategies and future expansion planning
At-a-glance: matching solutions to needs
-
Electric steam generators
- Best for: OR sterilizers, outpatient centers, labs, and small-to-mid SPDs
- Advantages: Compact, quiet, simplified utilities, fast installation
-
Packaged boilers
- Best for: Large hospitals, multi-sterilizer arrays, and high-throughput SPDs
- Advantages: Higher capacity, robust distribution, scalable
-
Skid-mounted packages
- Best for: Tight timelines or constrained spaces
- Advantages: Pre-engineered, faster commissioning, fewer unknowns
-
Feed/condensate systems
- Best for: Any steam plant seeking reliability and efficiency
- Advantages: Stable feedwater, improved efficiency, protects boiler internals
-
Water treatment and blowdown systems
- Best for: Facilities addressing scale/corrosion or meeting strict steam quality standards
- Advantages: Longer equipment life, fewer faults, better sterilization outcomes
Turnkey services from Auxo Medical
-
Site assessment and specification
- Demand analysis, space evaluation, and utility review
- System selection and right-sizing for performance and efficiency
-
Installation and startup
- Rigging, piping, electrical, venting, and controls integration
- Commissioning, verification, and operator training
-
Preventive maintenance and support
- Scheduled inspections, descaling, element and gasket replacements
- Safety and relief valve testing, blowdown optimization, controls checks
- Water testing guidance and treatment program support
-
Repairs, parts, and upgrades
- Rapid response for downtime-critical environments
- OEM and high-quality compatible parts
- Control retrofits, insulation upgrades, and energy-saving enhancements
-
Documentation and compliance
- Maintenance records, test logs, and calibration support to satisfy accreditation audits
- Coordination with local authorities and inspectors where required
Best practices for long-lived, reliable steam
- Protect water quality: Use softening or RO/DI as recommended for your sterilization equipment to limit scale and residue.
- Manage TDS and blowdown: Routine blowdown and sampling keep your system efficient and reduce carryover.
- Inspect regularly: Verify traps, PRVs, safety reliefs, and separators to prevent energy loss and unsafe conditions.
- Track performance: Log pressure/temperature, cycle times, and alarms to catch issues before they impact uptime.
- Plan redundancy: Consider N+1 or modular approaches to avoid a single point of failure for sterilization.
FAQs
- Do I need a dedicated steam generator for my sterilizers?
Many facilities choose dedicated generators to isolate medical steam from building loads, improving steam quality and reliability. - Electric or gas?
Electric steam generators are compact, quiet, and simple to install—great for small to mid-sized demands. Gas-fired boilers often deliver lower operating costs at higher loads. - How important is water quality?
Critical. Proper treatment extends equipment life and supports consistent sterilization results. Auxo Medical can help you select the right treatment and monitoring approach for your equipment and local water. - Can Auxo Medical service and maintain our existing system?
Yes—Auxo supports installation, PM, troubleshooting, and repairs, and can help retrofit or replace aging equipment.
Why partner with Auxo Medical?
- Healthcare-focused expertise in sterile processing and lab environments
- Full lifecycle support: consult, install, verify, maintain, and repair
- Options to fit your facility: new and pre-owned equipment availability
- Responsive service aimed at maximizing uptime and compliance
Let’s design the right steam solution for you
Whether you’re outfitting a new sterile processing department, upgrading legacy equipment, or solving recurring steam issues, Auxo Medical can help. Contact us to schedule a site assessment or request a quote for boilers, steam generators, feedwater systems, and accessories tailored to your facility.
-
Reimers All Stainless 40KW, 480V Steam Generator
The Reimers All Stainless 40KW, 480V Steam Generator is a high-quality, ASME-certified miniature boiler designed for reliable high-pressure steam production in demanding industrial and medical applications. Constructed entirely of 316 series Austenitic Stainless Steel, its wetted parts—shell, controls, heating elements,… -
Reimers All Stainless 20KW, 480V Steam Generator
The Reimers All Stainless 20KW, 480V Steam Generator is a high-capacity, ASME-compliant boiler engineered for reliable saturated steam production. All wetted parts are 316 stainless steel, with robust controls including adjustable pressure, manual reset high-limit, and integrated low-water protection. SRH… -
Chromalox Steris Powerpack CH13 CES150 480V Boiler
The Chromalox Steris Powerpack CH13 CES150 is a 150kW electric steam generator designed to deliver high-quality (97%) clean steam for powering connected equipment. Operating at 480V 3ph, this boiler features automatic controls for water level and steam pressure, including a… -
Reimers Timer Boiler On/Off
Reimers offers a timer-based Boiler On/Off control solution designed for systems requiring automated shutdown and startup, making it suitable for continuous 24/7 operations. This programmable system allows users to schedule boiler operation, ensuring efficient energy use and reducing the need… -
Reimers AR3 10lbs/hr 3kW 120V Steam Boiler
The Reimers AR3 is a compact, 3kW, 120V steam boiler designed for small-scale steam applications, delivering 10lbs/hr of high-quality saturated steam. With a maximum vessel volume of 0.29 ft³ and a safety valve setting of 100psi, this miniature boiler adheres… -
Reimers 180kW Vertical Boiler – 208V
The Reimers 180kW Vertical Boiler (208V) is engineered for space efficiency, featuring a vertical design that minimizes floor space requirements. This compact boiler has a maximum vessel volume of 5ft³ and a safety valve setting of 100psi. Manufactured in accordance… -
Reimers 195kW Vertical Boiler – 480V
The Reimers 195kW Vertical Boiler (480V) is a compact, space-saving solution for steam generation, featuring a vertical design and a miniature vessel volume of 5ft³. Built to meet A.S.M.E. standards, it operates between 0 and 85psig and includes essential safety… -
Pacific Steam 30kw 240V 1 PH Steam Generator
The Pacific Steam 30kw 240V 1 PH Steam Generator is a robust and efficient solution for steam production, designed with both functionality and ease of maintenance in mind. This steam generator features two 3-1/8” diameter hand holes that facilitate quick… -
Reimers 60kW Vertical Boiler – 480V
The Reimers 60kW Vertical Boiler, operating at 480V, exemplifies efficiency and safety in modern steam boiler design. This model, with its vertical configuration, demands minimal floor space, making it ideal for small industrial or commercial applications. Despite its compact size,… -
Reimers All Stainless 60KW, 480V Steam Generator
The Reimers All Stainless 60KW, 480V Steam Generator is a robust, ASME-certified miniature boiler engineered for consistent high-pressure steam production in industrial and medical environments. Constructed entirely from 316 series Austenitic Stainless Steel, all wetted components—including the shell, controls, and… -
Pacific Steam 30kw 240V Steam Generator
Specially designed for quick replacement & easier service Two 3-1/8” diameter hand holes for easy clean-up • 4.5”x4.5” flange mount single heating element Separate on-off switch on the cabinet Innovative probe system External piping furnished in brass or bronze •… -
Reimers All Stainless 80KW, 480V Steam Generator
The Reimers All Stainless 80KW, 480V Steam Generator is a high-capacity, ASME-certified miniature boiler designed for reliable high-pressure steam production in industrial and medical settings. Constructed entirely from 316 series Austenitic Stainless Steel, all wetted parts—shell, controls, heating elements, and… -
120 KW, 480V Steam Generator with Condensate Return Tank
Miniature boiler max. vessel volume 5ft3 • Maximum safety valve setting 100psi • All boilers are manufactured in accordance with the requirements of the A.S.M.E. Boiler and Pressure Vessel Code and A.S.M.E. CSD‐1. Each boiler bears the National Board Stamp… -
Chromalox Powerpack CH08 75kW Vertical Steam generator
Provides high-quality (97%) vapor quality clean steam needed to power connected equipment. Automatic controls include heating section water level control and steam pressure controls to control operating pressure and monitor high pressure limit. Auxiliary low water cut-off feature turns off… -
Chromalox Steris Powerpack CH10 102kW Vertical Steam generator
Provides high-quality (97%) vapor quality clean steam needed to power connected equipment. Automatic controls include heating section water level control and steam pressure controls to control operating pressure and monitor high-pressure limit. Auxiliary low water cut-off feature turns off heating… -
Reimers R 120 KW 480V Steam Generator
All boilers are manufactured in accordance with the requirements of the A.S.M.E. Boiler and Pressure Vessel Code and A.S.M.E. CSD Each boiler bears the National Board Stamp Miniature boiler max. vessel volume 5ft3 Maximum safety valve setting 100psi High quality…

























